Inter-Tel recommends installing a backup power supply unit having the following characteristics:
The ampere-hour rating of the battery determines the system back-up time. Also, even if the
power supply unit possesses the specifications listed in the preceding paragraph, it cannot be
guaranteed that it will work properly with the Inter-Tel system. Contact the Inter-Tel
CommSource division for a listing of approved UPS/SPS units.

UPS Monitoring

For correct operation, the UPS Monitoring feature requires compatible hardware and software,
as described in the following sections. An expanded description of the UPS Monitoring feature
and for Flags associated with UPS Monitoring, refer to the Inter-Tel 5000 Features and
Programming Guide (part no. 580.8006). For information about hardware and software
specifications that apply to the UPS Monitoring feature, see
instructions, see "Equipment to Support UPS Monitoring" on

Compatible UPS Units

Three commercial UPS units have passed UPS Monitor-compliance testing for use with the
Inter-Tel 5000 platform.
Monitoring capabilities of the following UPS units were found compatible with the UPS
Monitoring feature:
NOTE

Compatible USB Hubs

Through Inter-Tel product testing and validation, the hubs shown in Table 4-4 and Table 4-5 on
page 4-8
The tables are intended only to identify the USB hubs tested and verified to be compatible with
UPS Monitoring at the time of this publication.
Note that some USB hubs that are compatible with the Inter-Tel CS-5200 and CS-5400
platforms are not compatible with the CS-5600 platform.
®
Inter-Tel
5000 Installation Manual – Issue 2.4, May 2008
Sine wave output
Transfer time of less than 20 msec
Low AC line transfer voltage, or cutoff circuit, of 100 VAC, minimum
®
APC Smart-UPS
series (Universal Serial Bus [USB] connection)
MGE Pulsar Evolution series (USB connection)
®
®
ONEAC ON
Series
in advanced interface mode (To connect, you must use the USB
cable provided by the manufacturer.)
Consider the following facts about the compatible UPS units:
Only monitoring capabilities were tested.
Only connection across USB is supported.
Other models/series available from APC, MGE, and ONEAC are not
supported.
The best choice of a UPS for a particular system depends on environmental
factors and a balance between rated load and desired runtime. Consult Inter-
Tel CommSource
suitable for particular system requirements.
If a USB hub is needed so that you can use more than one USB port function
at the same time, use only the USB hubs that have been tested and validated
as compatible with the UPS Monitoring feature. For more information about
compatible USB hubs, see
have been identified as compatible with the Inter-Tel 5000 UPS Monitoring feature.