15.5.2 Checking the direction indicators

Check using the Multimeter the voltage U located
between the contact in the direction indicator
housing (positive terminal) and the bulb socket
(negative terminal).
Voltage in:
6 km/h wheelchair
10 km/h wheelchair (abroad)
10 km/h wheelchair (Deutschland)= 12 V
Caution:
Avoid bridging the poles whatever happens.
Danger of fire and combustion !

15.5.3 Reassembly of the direction indicators

Insert the new light bulb.
Type of bulb:
6 km/h wheelchair
10 km/h wheelchair (abroad)
10 km/h wheelchair (Deutschland)= 12 V / 10 W
Lock light bulb by slightly pressuring down and
turning by 1/8 rotation to the right.
Fit direction indicator glass.
Attach the direction indicator glass using the
fastening screw.
Note:
When reassembling the direction indicator
glass, ensure that the lug on the glass locates in
the groove in the direction indicator housing.
= 24 V
= 24 V
= 24 V / 10 W
= 24 V / 10 W
Page 148
Service Manual
Check voltage
Fit direction indicator
Groove in direction
Direction
Issued:21.01.02
+
U
-