Disassembly Of Control; Reassembling The Control; Disassembly Of The Motor; Reassembly Of The Motor - Invacare Twister Service Manual

Wheelchairs
Hide thumbs Also See for Twister:
Table of Contents

Advertisement

Twister / Twister Junior
Check
Check electrical functions
on control!
BUS plug defective?
BUS cable damaged?
Drive lever tight or
damaged?
Screw connections loose?
Parts / Support defective?
Motor defective?
Switchbox damaged?

19.5.1 Disassembly of control

Detach BUS cable (26) from the control (1).
Loosen screw (30), open clamp (29), and detach control (1) from its attachment.

19.5.2 Reassembling the control

Reassembly takes place in the reverse order.

19.5.3 Disassembly of the motor

Detach motor connection cable (38) from wheelchair and lay bare.
Remove securing ring (17) from bolt (14) so that the motor (8) can be freed from the back
support rod (2).
Loosen nut (37) completely and detach together with washer (25).
Support motor (8), remove screw (19) and detach motor from swivel arm (3).

19.5.4 Reassembly of the motor

Reassembly takes place in the reverse order.
Issued: 21.01.02
Remedy
⇒ See chapter 18.2.
⇒ Replace BUS cable.
⇒ Replace BUS cable.
⇒ Replace control.
⇒ Tighten screws.
⇒ Replace parts / support.
⇒ Replace motor.
⇒ Replace switchbox.
Page 185
Service Manual
Note:
On the motor, a continuity
test can be performed.
Also, a performance test
can be performed by
applying a voltage (24 V).
The tests must be
performed in the same
way as described in chapt.
17for the actuator motors.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Twister-junior

Table of Contents