Ricoh Toscana-P1 J007 Service Manual page 162

Machine code: j007/j010/j011
Table of Contents

Advertisement

If any item other than "0" is selected that item and its setting is enabled and takes priority.
[0 to 6/0/1/---]
Print Head Temperature Thresholds
1300 HTEMP:H:STOP
1301 HTEMP:H:JUDG
1302 HTEMP:H:RCVR
1303 HTEMP:L:RCVR
1304 HTEMP:L:JUDG
1305 HTEMP:L:STOP
Use this SP to set the threshold for the operating temperature range of the print head.
[0 to 1000/0/1/0.1
Ambient Temperature Thresholds
1306 ETEMP:H:STOP
1307 ETEMP:H:JUDG
1308 ETEMP:H:RCVR
1309 ETEMP:L:RCVR
1310 ETEMP:L:JUDG
1311 ETEMP:L:STOP
Use this SP to set the threshold for the operating humidity range of the print head.
[0 to 1000/0/1/0.1
Trigger Shutdown: Standby, Printing
Trigger Shutdown: Power On
Recovery After High Temp Shutdown
Recovery After Low Temp Shutdown
Trigger Shutdown: Power On
Trigger Shutdown: Standby, Printing
o
C
High Temperature to Trigger Shutdown: Standby, Printing
High Temperature to Trigger Shutdown: Power On
Recovery After High Temp Shutdown
Recovery After Low Temp Shutdown
Low Temperature to Trigger Shutdown: Power On
Low Temperature to Trigger Shutdown: Standby, Printing
o
C