HVAC SYSTEM (HEATER, VENTILATOR AND A/C)
Tools and Equipment
Syringe
A graduated plastic SYRINGE will be needed to add oil back into the
system. The syringe can be found at a pharmacy or drug store.
Vacuum pump
A VACUUM PUMP (in good working condition) is necessary, and may
be obtained from either a commercial refrigeration supply house or an
automotive equipment supplier.
Can tap
A CAN TAP for the 397 g (14 oz) can is available from an auto supply
store.
Thermometer
Pocket THERMOMETERS are available from either industrial hard-
ware store or commercial refrigeration supply houses.
Electronic leak detector
An ELECTRONIC LEAK DETECTOR can be obtained from either a
specialty tool supply or an A/C equipment supplier.
GENERAL DESCRIPTION
AC-18
Description
G4M0575
G4M0576
G4M0577
G4M0578
G4M0579