Correction For Paper Width And Thickness (By-Pass Tray Only) - Gestetner B003 Service Manual

Table of Contents

Advertisement

Rev. 09/2002

Correction for paper width and thickness (by-pass tray only)

The by-pass tray can be used for non-standard paper narrower than sizes
accepted by the paper trays. Thicker paper, OHP sheets, etc. can also be loaded in
the by-pass tray but adjustments must be performed with the SP modes listed
below in order to avoid jams and copy quality problems.
SP Mode
SP2-001-1
Charge Roller Bias Adjustment
SP2-309-1
Paper Lower Width [a]
SP2-309-2
Paper Upper Width [b]
SP2-914-1
SP2-914-2
The way that these SP modes are used is shown below.
0 mm
SP2-001-1 + SP2-914-1
Default: -1480+250 V
For example, with the default settings, if the paper width fed from the by-pass tray
is 200 mm, the charge roller voltage will be –1480 V + 50 V.
SM
SP Name
SP 2-309-1
Default: 150 mm
Voltage:
Voltage:
SP2-001-1 + SP2-914-2
Default: -1480+50 V
6-45
Width 216 - 297 mm
Width limit: 150 mm
Width limit: 216 mm
Adjust 10V/step
Adjust 10V/step
SP 2-309-2
Default: 216 mm
Voltage:
SP2-001-1
Default: -1480 V
B003/B004/B006/B007
DRUM CHARGE
297 mm
B004D507.WMF