Gestetner B003 Service Manual page 710

Table of Contents

Advertisement

G3-2 Switch 08 - Not used (do not change the settings)
G3-2 Switch 09 - Not used (do not change the settings)
G3-2 Switch 0A
No
FUNCTION
0
Maximum allowable carrier
1
drop during image data
reception
Bit 1
Bit 0
0
0
0
1
1
0
1
1
2-3
Not used
4
Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
5
Not used
6
Reconstruction time for the first
line in receive mode
0: 6 s 1: 12 s
7
Not used
SM
These bits set the acceptable modem carrier drop
time.
Try using a longer setting if error code 0-22 is
Value (ms)
frequent.
200
400
800
Not used
Do not change the settings.
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
Do not change the setting.
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data and
sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
Do not change the setting.
3-53
BIT SWITCHES
SP No. 1-106-011
COMMENTS
B003/B004/B006/B007