Test Pattern Printing: Sp2-902; Test Pattern Table (Sp2-902-2: Ipu Test Print) - Gestetner B003 Service Manual

Table of Contents

Advertisement

5.1.3 TEST PATTERN PRINTING: SP2-902

NOTE: Always print a test pattern to confirm correct operation of the machine.
1. Enter the SP mode and select SP2-902.
2. Press * or +.
• * IPU Test Print
• + Test Pattern
3. Enter the number for the test pattern that you want to print and press '. (See
the tables below.)
4. When you are prompted to confirm your selection, press Yes. This selects the
test pattern for printing.
5. Press Copy Window to open the copy window and then select the settings for
the test print (paper size, etc.)
6. Press Start ( twice. (Ignore the "Place Original" messages) to start the test
print.
7. Press SP Mode (highlighted) to return to the SP mode display.

Test Pattern Table (SP2-902-2: IPU Test Print)

No.
Test Pattern
0
None
1
Vertical Line (1-dot)
2
Horizontal Line (1-dot)
3
Vertical Line (2 dot)
4
Horizontal Line (2-dot)
5
Alternate Dot Pattern
6
Grid Pattern (1-dot)
7
Vertical Strips
SM
SERVICE PROGRAM MODE
No.
Test Pattern
8
Grayscale (Horizontal)
9
Grayscale (Vertical)
10
Cross Pattern (8)
11
Cross Shape
12
Argyle Pattern
13
Cross Pattern (256)
14
Cross Pattern (64)
5-47
B003/B004/B006/B007

Advertisement

Table of Contents
loading

This manual is also suitable for:

B004B006B007350245023502p ... Show all

Table of Contents