PRINTER INSTALLATION
[B]
B361I114.WMF
[F]
[G]
14. Install the paper height sensor feeler [A] on the bottom plate shaft [B] of each
paper tray.
15. Reassemble the machine.
Paper Limit Sensor Installation
If the optional bridge unit has been installed, skip steps 16 and 17.
16. Peel off the black tape [C] from the anti-static brush [D], then pull out the cable
[E].
17. Connect the cable to the sensor [F], then install the paper limit sensor unit [G]
(2 screws).
B003/B004/B006/B007
[A]
B361I116.WMF
1-4
[D]
[C]
[E]
B361I115.WMF
SM