SERVICE PROGRAM MODE
SP5
Mode Number
5828*
36
37
38
39*
40
47*
48*
49*
50*
51*
52*
53*
65,
66,
69
5833
5834
B003/B004/B006/B007
Network AppleTalk
Module Setting
Network NetNo Setting
(AppleTalk)
Network Object Name
Setting (AppleTalk)
Network AppleTalk Type
Setting
Network Working Zone
Setting (AppleTalk)
Network Job Analysis
Timeout Setting
(Centronics)
Network Job Timeout
Setting (Centronics)
Network Noise Cancel
Setting (Centronics)
Network 1284
Compatibility Setting
(Centronics)
Network Data Transfer
Speed Setting
(Centronics)
Network ECP Setting
(Centronics)
Network Transmission
Speed Setting
For Japanese models only
Job Log Transfer On/Off
Setting
Enable Operation Panel
Image Settings
Function and [Setting]
Sets the AppleTalk module for the network.
2: EtherTalk Phase2
Sets the NetNo of AppleTalk network.
Sets the object name of AppleTalk network.
Sets the AppleTalk type for the network.
Sets the AppleTalk working zone for the network.
Sets the Centronics job analysis timeout for the
network.
[0~4200 s / 3 s / 1 sec. step]
Sets the Centronics job timeout for the network.
[0~4200 s / 0 s / 1 sec. step]
Sets the noise cancel level for the network.
[4~7 / 4 / 1 clock per step]
Switches Centronics IEEE1284 compatibility
on/off for the network.
0: Disabled, 1: Enabled
Selecting "0" disables bi-directional data
transmission.
Sets the Centronics transfer speed for the
network.
0: SLOW, 1: FAST
If you select "0" there will be a 120
the STP signal to the data transfer. (With 1: FAST
there is no delay.)
Switches the ECP setting for Centronics off/on.
0: Disabled, 1: Enabled
With "1" selected, SP5-828-050 must be enabled
for 1284 mode compatibility.
Selects the Ethernet transmission speed.
[0x00~0x03 / 0x00 / 0x01 step]
Bit1
Bit2
Speed
0
0
Auto Sense
0
1
10Base-T
1
0
100Base-Tx
1
1
Auto
Please do not adjust these modes, they will not
function correctly even if the settings are
changed.
Switches the job log transfer on/off for Poplar
server.
0: Off (disable), 1: On (enable)
Enables and disables the operation panel read
(dump) feature. After powering on the machine,
set this option to 1 to enable this feature.
0: Off (disable), 1: On (enable)
To reset the machine to 0, the machine must be
turned off and on again. Selecting 0 for this option
without cycling the power off and on does not
restore the default setting (0).