Gestetner B003 Service Manual page 704

Table of Contents

Advertisement

G3 Switch 0B
No
FUNCTION
0
Protocol requirements: Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
6
Not used
7
DTS requirements : Germany
0: Disabled 1: Enabled
G3 Switch 0C
No
FUNCTION
0
Pulse dialing method
1
Bit 1 Bit 0
Setting
0
0
Normal(P=N)
0
1
Oslo (P=10 - N)
1
0
Sweden
(N+1)
1
1
Not used
2-7
Not used
G3 Switch 0D
No
FUNCTION
0-1
Not used
2
Data rate threshold during V.34
to
reception
5
Bit 5 4 3 2 Setting
0 0 0 0 Normal
0 1 1 1 Lower by
1 1 1 1 Lower by
6
Not used
7
B signal detection time for V.34
polling transmission
0: 75 ms (default setting)
1: 65 ms
SM
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
Do not change the setting.
Change this bit manually if required.
P = Number of pulses sent out, N = Number dialed.
Do not change the settings.
Do not change the settings.
The machine changes the modulation parameters in
the MPh signal to lower the initial modem rate
during V.34 reception. If this switch is set to "0111",
the machine lowers the initial speed one step, for
example, from 28,800 to 26,400 bps.
one step
This switch reduces transmission time if the
machine frequently sends PPR signals during V.34
two steps
reception.
Do not change the setting.
Change this switch only when there are
communication errors during V.34 polling
transmission to a machine with a Panasonic
modem.
3-47
BIT SWITCHES
SP No. 1-105-012
COMMENTS
SP No. 1-105-013
COMMENTS
SP No. 1-105-014
COMMENTS
B003/B004/B006/B007

Advertisement

Table of Contents
loading

This manual is also suitable for:

B004B006B007350245023502p ... Show all