SERVICE PROGRAM MODE
• Referring to the SMC data lists, re-enter any values, which had been
changed from their factory settings.
• Do SP 3-001-2 (ID Sensor Initial Setting) and SP4-911-1 (HDD media
check).
6. Check the copy quality and the paper path, and do any necessary adjustments.

5.1.9 SOFTWARE RESET

The software can be reboot when the machine hangs up. Use the following
procedure.
Turn the main power switch off and on.
-or-
Press and hold down ! ' together for over 10 seconds. When the machine
beeps once release both buttons. After "Now loading. Please wait" is displayed for
a few seconds the copy window will open. The machine is ready for normal
operation.

5.1.10 SYSTEM SETTINGS AND COPY SETTING RESET

System Setting Reset

The system settings in the UP mode can be reset to their defaults. Use the
following procedure.
1. Press User Tools/Counter
2. Hold down ' and then press System Settings.
NOTE: You must press ' first.
3. When the message prompts you to confirm that you want to reset the system
settings, press Yes.
4. When the message tells you that the settings have been reset, press Exit.