A682I113.WMF
3. Remove the middle front cover [A], and pull out the front handles [B].
4. Using the front handles and rear handles, lift the machine and hold it over the
paper tray unit [C].
5. Slowly lower the main machine onto the paper tray unit with the pegs [D]
aligned with the peg holes on the bottom of the machine.
NOTE: Do not hold the scanner unit.
6. Re-install the middle front cover [A].
7. Attach the lock washer [E] to the short knob screw [F]. Then, secure the paper
tray unit to the machine (! x1, lock washer).
8. Open the right cover of the paper tray unit [G].
9. Secure the joint bracket [H] (! x 1).
10. Remove the connector cover [I] of the main machine (! x1).
11. Connect the paper tray unit harness [J] to the main machine and re-attach the
connector cover.
SM
PAPER TRAY UNIT INSTALLATION
[D]
[D]
[H]
1-19
[J]
[I]
[G]