Resets; Memory All Clear: Sp5801 - Ricoh B132 Service Manual

Table of Contents

Advertisement

RESETS

5.2 RESETS

5.2.1 MEMORY ALL CLEAR: SP5801

Before shipping, the SP mode data settings are printed in an SMC Report and
attached to the exposure glass of the machine for your reference. Store this report
in a safe place (next to the toner collection bottle, for example). It is a list of all the
SP initial settings. Refer to this list if you need to initialize one or more SPs. The
initial SP settings are also written in the SP mode tables at the end of this section.
As a rule, you should always print an SMC Report before initializing or adjusting
the SP settings. The SMC Report provides a concise list of all the SP commands
and their current settings. The report can be used for reference if the service
manual is not available.
Executing Memory All Clear resets all the settings stored in the NVRAM to their
default settings except the following:
SP8381
SP5811-002:
SP5907:
1. Execute SP5990 to print out all SMC Data Lists.
2. Open SP5801.
3. Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to
initialize all modules.
B132/B200
Electrical total counter value
Machine serial number
Plug & Play Brand Name and Production Name Setting
5-6
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B200

Table of Contents