Ricoh B132 Service Manual page 505

Table of Contents

Advertisement

011 Fuse Exit Temp
012 Add Rot Time
Stand Cool On/Off
013 Thk2 (0:Off 1:On)
To Cooling Mode
014 Thk2/OHP Cool End
015 Trace Cool End
Edge Cool On/Off
016 Start (0:No 1:Yes)
SM
The temperature used to calculate the temperature
specified for the hot roller at the end of fusing/exit motor
rotation when the warmup temperature has been reached.
[0~30/1 deg. ]
The amount of time added to the rotation time of the
fusing/exit motor after warmup temperture has been
reached, based on the temperature specified for the hot
roller at standby.
[0~90/10]
Standby Ventilation Cooling: On/Off
Switches on/off standby for cooling after printing thick
paper.
0: Off 1: On
Standby Ventilation Cooling: Setting
Sets the temperature to end the cool down period after
printing with thick paper or OHP.
[0~40/1 deg. ]
Sets the temperature to end the cool down period after
printing with tracing (thin) paper.
[0~40/1 deg. ]
Standby Ventilation Cooling: On/Off High Edge Temp.
Switches on/off standby for cooling for the ends of the
fusing rollers after printing on wide paper.
0: Off 1: On