SERVICE CALL CONDITIONS
SC420
C
Potential sensor error 1: Vd Adjustment K
SC421
C
Potential sensor error 2: Vd Adjustment M
SC422
C
Potential sensor error 3: Vd Adjustment C
SC423
C
Potential sensor error 4: Vd Adjustment Y
The development potential of
the drum before exposure (Vd)
cannot be adjusted to within
±10 V of the target voltage (-
900V).
SC424
C
Potential sensor error 5: Vl adjustment K
SC425
C
Potential sensor error 6: Vl adjustment M
SC426
C
Potential sensor error 7: Vl adjustment C
SC427
C
Potential sensor error 8: Vl adjustment Y
Vpl could not be adjusted to
within ±10V of the target Vpl
after exposure of the ID sensor
patterns.
SC432
C
SC433
C
SC434
C
SC435
C
SC436
D
SC437
D
SC438
D
SC439
D
B132/B200
Potential sensor error 1: Vr K
Potential sensor error 2: Vr M
Potential sensor error 3: Vr C
Potential sensor error 4: Vr Y
Vr > 200V
The residual voltage (Vr), the amount
of voltage that remains on the surface
of the drum after the QL fires is
greater than 200V.
Potential sensor error 5: Vd K
Potential sensor error 6: Vd M
Potential sensor error 7: Vd C
Potential sensor error 8: Vd Y
The VdHome reading, the first step of
the process control self-check,
detected that the development
potential of the unexposed areas of
the drum are not within the prescribed
range (-500 to -700)
• Toner density low
• Toner density low
• Toner density low
• Potential sensor dirty
• Potential sensor defective
• Charge roller defective
• Charge power pack defective
• OPC defective