19. Place the development unit [A] inside
the disposal bag [B] provided.
20. Rotate the development unit down,
then rotate the lock gear [A] in the
direction of the arrow to dump the
developer/toner onto the paper.
Important
• Rotate the lock gear in the direction
indicated by the arrow. To avoid
damaging the entrance seal, do not
rotate the lock gear in the opposite
direction.
21. After dumping as much developer as possible, vacuum the remaining
developer and toner.
Important: Be sure to vacuum completely, especially around the
development roller.
22. Remove the lock gear and long special tool from the PCU.
23. Shake the new developer cartridge [F] from side to side about 6 times.