SERVICE PROGRAM TABLES
1106
Fusing Temp Disp
These SP codes control the temperature control of the hot roller and display the
temperatures of the hot roller, pressure roller, heating roller, and heating roller
lamps.
001 Temp Ctrl On/Off
002 Phase Ctrl On/Off
003 Htg Roll Ctr Temp
004 Htg Roll End Temp
005 Press Roll Temp
006 Hot Roll Temp
1107
Mode Shift Setting
Mode Shift
001 Low Temp SW
002 High Temp SW
003 Pres Roll Reload
004 Idle Temp On/Off
005 Idle Time:Extend
006 Feed Norm Temp
007 Press Temp:Norm
008 Press Time:Norm
009 Fuse Exit M Cycles
010 Fuse Exit M Rot
B132/B200
Fusing Lamp Control Method/Temperature Display
Hot roller fusing lamp control switch
0: OFF, 1: PID
Hot roller phase control
0:OFF 1:ON
Displays the temperature in centigrade of the fusing lamp
(center) in the heating roller. Range: 0 to 230
Displays the temperature in centigrade of the fusing lamp
(ends) in the heating roller. Range: 0 to 230
Displays the temperature in centigrade of the pressure
roller. Range: 0 to 230
Displays the temperature in centigrade of the hot roller.
Range: 0 to 230
Mode Shift Setting
Mode Shift Setting
The calculated value for the specified temperatures when
the readings of the environmental sensors are low.
[0~20/1 deg.]
The calculated value for the specified temperatures when
the readings of the environmental sensors are high.
[-20~0/1 deg.]
Press Roll Reload
The hot roller temperature that determines whether the
fusing unit rollers are rotated freely during warmup.
[80~200/1 deg.]
The length of time the fusing/exit motor remains on after
the fusing unit has reached the warmup temperature.
[0~10/1 min.]
Determines whether fusing exit motor remains before
feeding plain paper after warmup temperature for the
heating roller has been reached.
0: No 1: Yes
The temperature calculated for the specified temperature
when the fusing/exit motor starts to rotate when plain
paper starts to feed.
[0~20/1 deg.]
The time calculated to be added to the rotation time of the
fusing/exit motor at the start of plain paper feed, based on
the temperature specified temperature.
The cycles of the fusing/exit motor at standby.
[10~240/1 min. ]
The time the fusing exit motor rotates at standby.
[0~1/1 ]
5-26