5816
Remote Service
001
I/F Setting
002
CE Call
003
Function Flag
006
Device
Information Call
Display
007
SSL Disable
008
RCG Connect
Timeout
009
RCG Write to
Timeout
010
RCG Read
Timeout
011
Port 80 Enable
SM
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
Lets the customer engineer start or end the remote machine
check with CSS or NRS; to do this, push the center report
key.
Enables and disables remote diagnosis over the NRS
network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
Controls if the item for initial setting of the screen for the NRS
device-information notification-call is shown.
[0~1/1]
0: Enabled. Item initial setting not shown.
1: Disable. Item for initial setting shown.
Controls if RCG (Remote Communication Gate) confirmation
is done by SSL during an RCG send for the NRS over a
network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
Sets the length of time (seconds) for the time-out when the
RCG (Remote Communication Gate) connects during a call
via the NRS network.
[1~90/1 sec.]
Sets the length of time (seconds) for the time-out when sent
data is written to the RCG during a call over the NRS
network.
[0~100/1 sec.]
Sets the length of time (seconds) for the timeout when sent
data is written from the RCG during a call over the NRS
network.
[0~100/1 sec.]
Controls if permission is given to get access to the SOAP
method over Port 80 on the NRS network.
[0~1/1]
0: No. Access denied
1: Yes. Access granted.