Ricoh B132 Service Manual page 519

Table of Contents

Advertisement

027 Y Sub Skew 3
030 MUSIC Result
2182
Skew Corr Total
These SPs display the total skew correction for magenta, cyan, and yellow.
001 M
[-50~+50/1 pulse]
002 C
[-33~+33/1 pulse]
003 Y
[-50~+50/1 pulse]
2183
2-Point Measure
These SPs allow you to set the focal points for the execution of 2-point
measurement of each color.
001 Focus Value:K
002 Focus Value:M
003 Focus Value:C
004 Focus Value:Y
2201
Set DC Charge
These SPs set the dc bias for the standard speed and low speed mode, but take
effect only when SP3501 001 is set to "1" (Fixed). The dc bias (an absolute value)
is set to +200, making the default values for each color –700. The dc bias is
normally adjusted by the process control self-check, but when automatic process
control is switched off (by setting SP3501 001 to "1"), these values are used for the
charge potential.
001 Std Speed:K
002 Std Speed:M
003 Std Speed: C
004 Std Speed: Y
006 Low Speed:K
007 Low Speed: M
008 Low Speed: C
009 Low Speed: Y
2202
Set AC Charge
These SPs set the AC bias for the standard speed mode and low speed mode,
but take effect only when SP3501 001 is set to "1" (Fixed). The default ac bias for
each color is 2.2 kV (220) The ac bias is normally adjusted by process control
self-check, but when automatic process control is switched off (by setting SP3501
001 to "1"), these values are used for the charge potential.
001 Std Speed: K
002 Std Speed: M
003 Std Speed: C
004 Std Speed: Y
006 Low Speed: K
007 Low Speed: M
008 Low Speed: C
009 Low Speed: Y
SM
Amount of shift correction for yellow in the sub scan
direction at sensor 3.
Displays the result of MUSIC adjustment
Skew Correction Total
2-Point Interval Measurement Monitor
[-100~+100/0.01%]
Fixed DC Charge Setting
[-999 to –200/1V]
Fixed DC Charge Setting
[0~300/1 kV]
5-41
SERVICE PROGRAM TABLES
B132/B200