2806
Sp2 FC Bias
These SPs set the standard values of the electrical charges that are applied to 1)
create bias for image transfer from drum of each color (Y, M, C, K) to the ITB, 2)
create bias for image transfer from ITB to paper (PTR), and 3) neutralize the
charges on the both sides of the paper to separate the paper from the ITB (SepDC,
SepAC). These settings are used only for Y, M, C, K when printing on Special
Paper 1 in the full-color mode and are applied only to the image area.
001 ITB:K
002 ITB:M
003 ITB:C
004 ITB:Y
013 Side1:PTR
014 Side1:SepDC
015 Side1:SepAC
021 Side2:PTR
022 Side2:SepDC
023 Side2:SepAC
These SPs (SP2811~SP2815) set the paper size correction coefficients for Special
Paper 2 relative to the settings done with SP2308 (Set Psize Thresh). All of hese
settings:
• Apply to printing on Special Paper 2 in the black-and-white mode
• Apply only to the image area
The title of each SP tells you the side and size where the setting is applied at ITB-
to-paper transfer, for example: "Side1:Size1:PTR" means the setting applies to
only Side 1 of Size 1 when the image is transferred from belt to paper at the PTR.
2811
Size Coeff:Sp2
007 Side1:Size1:PTR
012 Side2:Size1:PTR
2812
Size Coeff:Sp2
007 Side1:Size2:PTR
012 Side2:Size2:PTR
2813
Size Coeff:Sp2
007 Side1:Size3:PTR
012 Side2:Size3:PTR
2814
Size Coeff:Sp2
007 Side1:Size4:PTR
012 Side2:Size4:PTR
2815
Size Coeff:Sp2
007 Side1:Size5:PTR
012 Side2:Size5:PTR
SM
Set Bias for Special Paper 2: K
[0~500/0.1 µa]
[0~500/0.1 µa]
[0~500/0.1 µa]
[0~500/0.1 µa]
[-100~0/1 µa]
[0~100/0.1 µa]
[80~120/0.1 kV]
[-100~0/1 µa]
[0~1000/0.1 µa]
[80~120/0.1 kV]
Size Correction Coefficient for Special Paper 2
SP2308 001 Threshold 1
[100~600/5%]
Size Correction Coefficient for Special Paper 2
SP2308 002 Threshold 2, < SP2308 001 Threshold 1
[100~600/5%]
Size Correction Coefficient for Special Paper 2
SP2308 003 Threshold 3, < SP2308 002 Threshold 2
[100~600/5%]
Size Correction Coefficient for Special Paper 2
SP2308 004 Threshold 4, < SP2308 003 Threshold 3
[100~600/5%]
Size Correction Coefficient for Special Paper 2
Up to SP2308 004 Threshold 4
[100~600/5%]