Syntax
up up-timeout
Context
config>eth-ring>ccm-hold-time
This command specifies the timer, which controls the delay between detecting that ring path is up and
reporting it to the G.8032 protection module. If a non-zero value is configured, the CPM will wait for
the time specified in the value parameter before reporting it to the G.8032 protection module. Note
that this parameter applies only to ring path CCM. It does NOT apply to the member port link state.
To damp member port link state transitions, use hold-time parameter from the physical member port.
Default
20 deciseconds
Parameters
value — Specifies the hold-time for reporting the recovery.
rpl-node
Syntax
rpl-node <owner | nbr>
no rpl-node
Context
config>eth-ring
This command configures the G.8032 ring protection link type as owner or neighbor. The no form of
the command means this node is not connected to an RPL link. When RPL owner or neigh is
specified either the a or b path must be configure with the RPL end command. An owner is
responsible for operation of the rpl link. Configuring the RPL as neighbor is optional (can be left as
no rpl-node) but if the command is used the nbr is mandatory.
The no form of this command removes the RPL link.
Default
no rpl-node
node-id
Syntax
node-id timeout
no node-id
Context
config>eth-ring
This optional command configures the MAC address of the RPL control. The default is to use the
chassis MAC for the ring control. This command allows the chassis MAC to be overridden with
another MAC address. This command is primarily used for configurations where
The no form of this command removes the RPL link.
Default
no node-id
Parameters
value — <xx:xx:xx:xx:xx:xx or xx-xx-xx-xx-xx-xx>
7210 SAS E Interface Configuration Guide
Values
0-5000 deciseconds