Power Cord Requirements for AC-Powered Switches and AC
Power Supplies
Power cords used with AC-powered Summit family switches or Summit AC power supplies must meet
the following requirements:
The power cord must be agency-certified for the country of use.
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
the minimum wire size is 16 AWG (1.0 mm

Console Connector Pinouts

The following table describes the pinouts for a DB-9 console plug connector.
Table 424: Pinouts for the DB-9 Console Connector
Function
DCD (data carrier detect)
RXD (receive data)
TXD (transmit data)
DTR (data terminal ready)
GND (ground)
DSR (data set ready)
RTS (request to send)
CTS (clear to send)
The following table shows the pinouts for a 9-pin to 25-pin (RS-232) null-modem cable.
Figure 364: Null-Modem Cable Pinouts
The following table shows the pinouts for a 9-pin to 9-pin (PC-AT) null-modem serial cable.
Summit Family Hardware Installation Guide
2
).
Pin Number
1
2
3
4
5
6
7
8
Technical Specifications
2
) minimum; over 6 feet,
Direction
In
In
Out
Out
-
In
Out
In
490