Adjusting Programs

3-13 Adjusting Programs

3-13-1 Changing the SP

3-13-2 Changing the Time

The temperature vector will change if the program is changed during opera-
tion when the Step Time/Rate of Rise Programming parameter is set to Step
Time. The following sections show how the temperature vector will changed.
If the SP is changed during a segment, the present SP will move in a straight
line with the changed SP as the target point.
Set point
Before change
After change
Point of change
Segment N
If the time is changed during a segment, the slope of the line along which the
present SP moves will change because the time taken to reach the target will
change.
Set point
Point of change
Before change
Segment N
Segment N
After change
If the segment time after the change is shorter than the elapsed segment
time, the program will immediately move to the next segment.
Segment N+1
Segment N+1
Segment N+1