Omron E5CN-HT User Manual page 377

Digital controllers programmable type
Hide thumbs Also See for E5CN-HT:
Table of Contents

Advertisement

Press the PF Key
for at least 1 s.
(See note 1.)
Press the O Key less than 1 s.
Program Setting Level
Display Program Selection
d.prg
d.prg
0
d.prg
d.prg
0
1
2
7
s-n o
Number of Segments
Used, 1 to 32
8
Display Segment Selection, END or 0 to
Number of Segments 1
d.seg
d.seg
end
d.seg
0
d.se g
1
7
PID Set No.
pid
Segment n Format
styp
0
ramp
M
M
Alarm Value 1
al-1
c
Segment n SP
c
sp
0.0
M
0.0
M
Alarm Upper
Ral1h
c
Limit 1
Segment n Ramp
Rpr
0.0
c
Rate
0.0
M
M
Alarm Lower
Ra l1 l
c
Limit 1
Segment n Time
time
0.0
M
0.00
M
Alarm Value 2
c
al-2
0.0
M
Program Link
lin k
Destination
Alarm Upper
Ral2h
c
end
Limit 2
0.0
M
M
ts1 s
Time Signal 1
Set Segment
Alarm Lower
Ral2l
0
Limit 2
0.0
M
M
Time Signal 1
on1
ON Time
Alarm Value 3
c
al-3
0.00
0. 0
M
M
Time Signal 1
of1
OFF Time
Alarm Upper
0.00
Ral3h
c
Limit 3
0.0
M
Time Signal 2
M
ts2s
Set Segment
Alarm Lower
al3l
0
c
Limit 3
0.0
M
M
Time Signal 2
on2
ON Time
Program
0.0 0
Rrp t
Repetitions
0
M
Time Signal 2
of2
OFF Time
0.00
Note:
1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN/EN-HT).
2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN/EN-HT).
Power ON
Starting in manual mode.
Manual Control Level
Press the O Key
PID
c
25 .0
Control
or the PF Key for
only
100.0
at least 1 s.
PV/MV
(See note 1.).
Operation Level
Operation Level
Press the
O Key for
at least 3 s.
PV
c
25.0
M
25.0
PV/SP
c
lcr 1
0.0
(See note.)
M
Auto/Manual
a-m
lcr 2
Switch
M
Program Number
prg
0
M
Segment No.
seg
Monitor
0
M
Hold
Hold
off
M
adv
Advance
off
M
Remaining Standby
stb m
Time Monitor
0.0 0
M
Elapsed Program
prg t
Time Monitor
0.00
M
Program Execution
rptm
Repetition Monitor
0
M
Remote SP Monitor
c
rsp
0.0
Heater Current 1
ct1
Value Monitor
0.0
M
Note Refer to PV/SP on page 185 for informa-
tion on displays for models that have a
No. 3 display (E5AN-H or E5EN-H).
PF Key (See note 2.)
Monitor/Setting Item Level
PF
25 .0
Monitor/Setting
Item Display 1
0.0
Monitor/Setting
PF
Item Display 4
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to
5 parameters (advanced function setting level).
Starting in
automatic
mode.
Press the O
and M Keys for
at least 3 s.
Heater Current 2
ct 2
Value Monitor
0.0
M
Leakage Current 1
Value Monitor
0.0
M
Leakage Current 2
Value Monitor
0.0
M
Run/Reset
r-r
Press the O
rst
and M Keys for
M
at least 1 s.
o
MV Monitor (Heating)
0.0
M
c- o
MV Monitor (Cooling)
0.0
M
V-m
Valve Opening
Monitor
0.0
M
(E5AN/EN-HT only)
Monitor/Setting
PF
Monitor/Setting
Item Display 2
Item Display 3
PF
Monitor/Setting
Item Display 5
PF Key (See note 2.)
Appendix
355