Table of Contents
18
Safety Precautions
7
Related Manuals
13
Conventions Used in this Manual
16
About this Manual
20
Gradient Temperature Control Setup
20
Troubleshooting
20
Section 1 Outline
22
Outline
22
Names of Parts
23
Appearance
23
Names of Parts on Front Panel
23
Meanings of Indicators
23
Using Setting Switches
24
Setting the Unit Number
24
I/O Configuration and Main Functions
26
I/O Configuration
26
Main Unit Functions
27
Model Number Legend
28
Internal Block Diagrams
30
Preparations
32
Installation
33
Mounting and Removing Terminal Blocks
34
Wiring Terminals
37
Terminal Arrangement
37
Wiring Precautions
39
Control Outputs
41
Using Tool Ports
46
Unit Configuration Examples
47
Connection Precautions
48
Gradient Temperature Control Setup
54
Setup Procedure
55
Adjusting Gradient Temperature Control
67
Changing Sps During Operation
68
Section 4 Basic Units (Tc4 and Tc2) Functions
70
Basic Units (TC4 and TC2) Functions
70
Setting Input Specifications
71
Input Type
71
Temperature Inputs
72
Analog Inputs
72
Input Filter
73
Setting Output Specifications
74
Control Output Method
74
Alarm Outputs (TC2 Units Only)
74
Setting Control Specifications
75
Manipulated Variable (MV)
75
Detecting Current Errors
76
Other Functions
77
Using G3ZA Multi-Channel Power Controllers
77
Section 5 Advanced Unit (Hfu) Functions
82
Advanced Unit (HFU) Functions
82
Setting Input Specifications
83
Input Type, Temperature Inputs, Analog Inputs, and Input Filter
83
Decimal Point Position B
83
Input Shift (Correction)
83
Setting Output Specifications
87
Control Output Method
87
Setting Control Specifications
88
Starting and Stopping Control
88
Selecting the Control Method
89
Setting the Set Point
92
Setting the SP Ramp
93
Setting the Manipulated Variable (MV)
95
Tuning
97
Disturbance Overshoot Adjustment Function
99
Operation During Errors
101
Setting Alarm Specifications
104
Alarm Types
104
Alarm Value
105
Alarm Hysteresis
105
Standby Sequence
106
Alarm Latch
107
Closed in Alarm or Open in Alarm
107
Alarm SP Selection
107
Channel Alarm Status
108
Detecting Current Errors
109
Heater Burnout Alarm (HB Alarm)
109
Heater Short Alarm (HS Alarm)
111
Programless Communications
114
Connectable Devices
114
Checking Operation
115
Detailed Settings
123
Description of Operation
129
Operation Command Codes for Programless Communications
138
Programless Communications Errors
141
Other HFU Functions
142
Bank Function
142
Event Inputs (TC2)
143
Auxiliary Output Allocations
144
Using G3ZA Multi-Channel Power Controllers
144
Section 6 Communications (Compoway/F)
146
Communications (Compoway/F)
146
Communications Settings
147
Communications Specifications
147
Unit Number Setting
148
Other Communications Settings
148
Send Data Wait Time
148
Frame Configuration
149
Response Frame
150
FINS-Mini Text
151
PDU Structure
151
Variable Type and Address
151
Number of Elements
151
Communications Data
152
List of FINS-Mini Command Services
152
Detailed Description of Services
153
Read from Variable Area
153
Write to Variable Area
154
Composite Read from Variable Area
155
Composite Write to Variable Area
156
Composite Registration Read
157
Composite Read Registration
158
Composite Read Registration Confirmation
159
Controller Attribute Read
160
Controller Status Read
161
6-4-10 Echoback Test
162
6-4-11 Operation Commands
163
Section 7 Errors and Error Processing
168
Errors and Error Processing
168
Things to Check First
169
Determining Errors from Indicators
170
Determining the Error from the Status
172
Determining the Error from the Current Situation for Communications Errors
179
Determining the Error from the Current Situation for Temperature Measurement Errors
184
Determining the Error from the Current Situation for Temperature Control Errors
185
Determining the Error from the Current Situation for Output Errors
187
Determining the Error from the Current Situation for Heater Burnout Alarm Errors
188
Appendix
190
Specifications
191
Ratings
191
Characteristics
192
Current Transformer
193
Specifications
193
Dimensions
193
ASCII Table
194
Sensor Input Ranges
195
Parameter List
196
Status Lists
209
Parameters that Can be Allocated for Programless Communications
227
Index
230
Revision History
236
Advertisement
OMRON EJ1G Datasheet (25 pages)
EJ1G Series Modular Temperature Controller for Gradient Temperature Control
Brand:
OMRON
| Category:
Temperature Controller
| Size: 1.75 MB
Table of Contents
Ordering Information
1
Specifications
2
Communications Specifications
4
Connection Precautions
9
Programless Communications
10
Safety Precautions
18
Precautions for Operation
19
Advertisement
Related Products
Omron EJ1G-TC2A-QNH
Omron EJ1G-TC2B-QNH
Omron EJ1G-TC4A-QQ
Omron EJ1G-TC4B-QQ
Omron EJ1G-HFUA-NFLK
Omron EJ1G-HFUB-NFLK
Omron EJ1G-HFUA-NFL2
Omron EJ1G-HFUB-NFL2
OMRON EJ1 EtherCAT
Omron EJ1N-TC4
OMRON Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More OMRON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL