Configuration Limits
Table 102: Fibre Channel Environments
Parameter
Device Aliases per fabric
Switches per physical fabric or VSAN
Domains per VSAN
Native FC Links per switch
FLOGIs or FDISCs per NPV port group
Zones per virtual or physical F port (includes all
VSANs)
Zone sets per switch (includes all VSANs)
Zone members per physical fabric (includes all
VSANs)
Zones per switch (includes all VSANs)
Maximum diameter of a SAN Fabric
FSPF interface instances per switch
ISL instances per switch
Virtual Fibre Channel interfaces
Max FCIDs allocated
Fibre Channel Flows
6 The switch is capable of supporting up to 239 switches per fabric but this is not currently implemented.
7 The switch is capable of supporting up to 239 domains per VSAN but the scale is not currently implemented.
8 The switch is capable of 1000 Zone Sets but this is not currently implemented.
9 The switch is capable of supporting up to 20,000 zone members per fabric but the scale is not currently implemented.
10 The switch is capable of supporting up to 12 hops but the scale is not currently implemented.
11 The switch is capable of supporting 4096 (the number of Extended ISLs (16) times the number of VSANs (256)) but the scale is not currently implemented.
12 Each ISL instance can support up to 32 VSAN instances.
13 The switch is capable of supporting 480 virtual Fibre Channel interfaces but the scale is not currently implemented.
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
700
Limit
8,000
6
50
7
40
16—Requires two N5K-M1008 expansion modules.
255
32
8
500
9
8,000
8,000
10
3 hops
11
512
12
256
13
160
2,048
32
Appendix