Configuring Domain Parameters
Step 3

Configuring Fabric Names

To set the fabric name value for a disabled fcdomain, perform this task:
Procedure
Step 1
Step 2
Step 3

About Incoming RCFs

You can configure the rcf-reject option on a per-interface, per-VSAN basis. By default, the rcf-reject option
is disabled (that is, RCF request frames are not automatically rejected).
The rcf-reject option takes effect immediately.
No fcdomain restart is required.
You do not need to configure the RFC reject option on virtual Fibre Channel interfaces, because these
Note
interfaces operate only in F port mode.

Rejecting Incoming RCFs

To reject incoming RCF request frames, perform this task:
Procedure
Step 1
Step 2
Step 3
OL-16597-01
Command or Action
switch(config)# fcdomain vsan vsan-id
Command or Action
switch# configuration terminal
switch(config)# fcdomain fabric-name
20:1:ac:16:5e:0:21:01 vsan vsan-id
switch(config)# no fcdomain fabric-name
20:1:ac:16:5e:0:21:01 vsan vsan-id
Command or Action
switch# configuration terminal
switch(config)# interface fc slot/port
switch(config-if)# fcdomain rcf-reject vsan
vsan-id
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
Configuring Fabric Names
Purpose
Enables the fcdomain configuration in the
specified VSAN.
Purpose
Enters configuration mode.
Assigns the configured fabric name value in
the specified VSAN.
Changes the fabric name value to the factory
default (20:01:00:05:30:00:28:df) in VSAN
3010.
Purpose
Enters configuration mode.
Configures the specified interface.
Enables the RCF filter on the specified interface
in the specified VSAN.