About Cfs Distribution Of Allowed Domain Id Lists; Enabling Distribution; Locking The Fabric - Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual

Cli software configuration guide
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

About CFS Distribution of Allowed Domain ID Lists

Step 3
About CFS Distribution of Allowed Domain ID Lists
You can enable the distribution of the allowed domain ID list configuration information to all Cisco SAN
switches in the fabric using the Cisco Fabric Services (CFS) infrastructure. This feature allows you to
synchronize the configuration across the fabric from the console of a single switch. Because the same
configuration is distributed to the entire VSAN, you can avoid possible misconfiguration and the possibility
that two switches in the same VSAN have configured incompatible allowed domains.
Use CFS to distribute the allowed domain ID list to ensure consistency in the allowed domain ID lists on all
switches in the VSAN.
We recommend configuring the allowed domain ID list and committing it on the principal switch.
Note
Related Topics

Enabling Distribution

CFS distribution of allowed domain ID lists is disabled by default. You must enable distribution on all switches
to which you want to distribute the allowed domain ID lists.
To enable (or disable) allowed domain ID list configuration distribution, perform this task:
Procedure
Step 1
Step 2
Step 3

Locking the Fabric

The first action that modifies the existing configuration creates the pending configuration and locks the feature
in the fabric. After you lock the fabric, the following conditions apply:
• No other user can make any configuration changes to this feature.
• A pending configuration is created by copying the active configuration. Subsequent modifications are
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
488
Command or Action
switch(config)# no fcdomain allowed
domain-id range vsan vsan-id
Using Cisco Fabric Services, page 299
Command or Action
switch# configuration terminal
switch(config)# fcdomain distribute
switch(config)# no fcdomain distribute
made to the pending configuration and remain there until you commit the changes to the active
configuration (and other switches in the fabric) or discard them.
Configuring Domain Parameters
Purpose
Reverts to the factory default of allowing domain
IDs from 1 through 239 in the specified VSAN.
Purpose
Enters configuration mode.
Enables domain configuration distribution.
Disables (default) domain configuration
distribution.
OL-16597-01

Advertisement

Table of Contents
loading

Table of Contents