Configuring Port Tracking
The specified VSAN does not have to be the same as the port VSAN of the linked port.

Monitoring Ports in a VSAN

To monitor a tracked port in a specific VSAN, perform this task :
Procedure
Step 1
Step 2
Step 3
Step 4

About Forceful Shutdown

If a tracked port flaps frequently, then tracking ports using the operational binding feature may cause frequent
topology change. In this case, you may choose to keep the port in the down state until you are able to resolve
the reason for these frequent flaps. Keeping the flapping port in the down state forces the traffic to flow through
the redundant path until the primary tracked port problems are resolved. When the problems are resolved and
the tracked port is back up, you can explicitly enable the interface.
If you configure this feature, the linked port continues to remain in the shutdown state even after the tracked
port comes back up. You must explicitly remove the forced shut state (by administratively bringing up this
interface) of the linked port once the tracked port is up and stable.

Forcefully Shutting Down a Tracked Port

To forcefully shut down a tracked port, perform this task:
Procedure
Step 1
Step 2
Step 3
Step 4
OL-16597-01
Command or Action
switch# configuration terminal
switch(config)# interface fc slot/port
switch(config-if)# port-track interface
san-port-channel 1 vsan 2
switch(config-if)# no port-track interface
san-port-channel 1 vsan 2
Command or Action
switch# configuration terminal
switch(config)# interface fc slot/port
switch(config-if)# port-track force-shut
switch(config-if)# no port-track
force-shut
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
Monitoring Ports in a VSAN
Purpose
Enters configuration mode.
Configures the specified interface and enters the
interface configuration mode. You can now
configure tracked ports.
Enables tracking of the SAN port channel in
VSAN 2.
Removes the VSAN association for the linked
port. The SAN port channel link remains in effect.
Purpose
Enters configuration mode.
Configures the specified interface and enters the
interface configuration mode. You can now
configure tracked ports.
Forcefully shuts down the tracked port.
Removes the port shutdown configuration for the
tracked port.
669