Lenovo ThinkEdge SE455 V3 User Manual page 102

Table of Contents

Advertisement

• If the server is installed in a rack, remove the server from the rack. See
on page
49.
Procedure
Step 1.
Make preparation for this task.
a.
Remove the top cover. See
b.
Remove all the fan modules. See
c.
Remove all the PCIe assemblies. If the configuration comes with PCIe riser 2 and internal
drives, remove all the internal drives, and lift the internal drive backplane before removing PCIe
riser 2. See
d.
Remove the processor air baffle. See
e.
Remove the fan cage. See
Step 2.
Disconnect all the cables from the fan control board.
Step 3.
Remove the fan control board.
a.
Loosen the thumbscrew that secures the fan control board.
b.
Slide the fan control board until the guide pins on the chassis are seated on the large
opening of the keyholes; then, lift the fan control board to remove it.
Figure 63. Removing the fan control board
After this task is completed
• Install a replacement unit. See
• If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Install the fan control board (FCB)
Follow the instructions in this section to install the fan control board (FCB).
About this task
S002
94
ThinkEdge SE455 V3 User Guide
"Remove the top cover" on page
"Remove a fan module" on page
"Remove the PCIe riser assembly" on page
"Remove the fan cage" on page
"Install the fan control board (FCB)" on page
"Remove the server from the rack"
223.
141.
"Remove the processor air baffle" on page
91.
89.
67.
94.