Ambient Storage Conditions; Ambient Installation Conditions - Delta ASDA-B3 Series User Manual

Hide thumbs Also See for ASDA-B3 Series:
Table of Contents

Advertisement

Installation

2.1 Ambient storage conditions

Before installation, this product must be kept in the shipping carton. In order to retain the
2
warranty coverage and for maintenance, follow these instructions for storage. While the product
is temporarily not in use:
 Store the product in an ambient temperature range of -20°C (-4°F) to +65°C (+149°F).
 Store the product in a relative humidity range of 0% to 90% (non-condensing).
 Avoid storing the product in an environment containing corrosive gas.

2.2 Ambient installation conditions

The ambient temperature of the operating environment for the servo drive is between 0°C
(32°F) and 55°C (131°F). During long-term operation, the suggested temperature of the
operating environment should be under 45°C (113°F) to ensure the servo drive's
performance.
2-2
B3 servo drive: the environment should be free of devices that generate
excessive heat; no water, water vapor, dust, and oily dust; no corrosive and
inflammable gas or liquids; no airborne dust or metal particles; and the
environment should be solid without vibration and interference of electromagnetic
noise.
Motor: the ambient temperature for the location of the ECM-A3 and ECMC
motors should be between 0°C (32°F) and 40°C (104°F). The ambient
temperature for the location of the ECM-B3 motors should be between -20°C
(-4°F) and +60°C (+140°F)*. The environment should be free of devices that
generate excessive heat; no water, water vapor, dust, and oily dust; no corrosive
and inflammable gas or liquids; and no airborne dust or metal particles.
Note: if the ambient temperature for the location of the ECM-B3 motors is over 40˚C, refer
to Section A.2.3 Power derating curves of the B3 motors.
Measuring
point
50 mm
(2 inch)
10 mm
(0.4 inch)
50 mm
(2 inch)
50 mm
(2 inch)
ASDA-B3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents