Test Operation and Panel Display

4.1 Panel description

4
(1) Display: 5-digit, 7-segment LED displays the monitoring codes, parameter numbers, and
setting values.
(2) MODE key: switches the display among Monitoring mode, Parameter mode, and Alarm
mode. In Editing mode, pressing the MODE key switches back to Parameter mode.
(3) UP (▲) key: changes the monitoring codes, parameter numbers, and setting values.
(4) CHARGE: the LED indicator is on when the power is applied to the main circuit.
(5) DOWN (▼) key: changes the monitoring codes, parameter numbers, and setting values.
(6) SHIFT key: in Parameter mode, pressing the SHIFT key changes the group number. In
Editing mode, pressing the SHIFT key moves the flashing (selected) digit to the left, so you
can adjust the higher setting bit. In Monitoring mode, pressing the SHIFT key switches the
display of high and low words.
(7) SET key: displays and saves the parameter setting value. In Monitoring mode, pressing the
SET key switches between decimal and hexadecimal display. In Parameter mode, pressing
the SET key switches to Editing mode.