Installing
2.3 Installing supplementary system components
Mounting the CX32-2 directly on a mounting surface
A spacer is pre-assembled on the CX32-2. To mount the CX32-2 directly on a mounting
surface, you must first disassemble the spacer as follows:
Table 2- 2
Disassembling the CX32-2 spacer
Loosen the screws on the mounting rail
(M3, Torx T10) and remove the rail.
38
Loosen the screws of the spacer (M3,
Torx T10) and remove the spacer.
Fasten the mounting rail to the CX32-2
again without spacer (tightening torque
0.8 Nm).
Commissioning and Hardware Installation Manual, 02/2012