Siemens SIMOTION D4 5-2 Series Commissioning And Hardware Installation Manual page 134

Hide thumbs Also See for SIMOTION D4 5-2 Series:
Table of Contents

Advertisement

Parameter assignment / addressing
5.5 Configuring an Ethernet subnet
Default Ethernet addresses
The following addresses are assigned per default:
Table 5- 5
Interface
X127 P1
PN/IE
X120 P1
PN/IE-OP
(only for D4x5-2
DP)
X130 P1
PN/IE-NET
Note
The IP addresses 192.168.215.240 to 192.168.215.255 are reserved for internal
communication in the SIMOTION D4x5-2 (subnet mask 255.255.255.240). When configuring
the external Ethernet interfaces (X127 P1, X120 P1 and X130 P1), make sure that the
internal addresses are not inside their network. (In IP, the network is defined as an AND link
of IP address and subnet mask.)
Note
If you want to go online via Ethernet, you have to make sure that the connection from PG/PC
to SIMOTION D4x5-2 is active. You can check this in NetPro. A description of how to switch
a connection to active again can be found in the Section Establishing the PG/PC assignment
(Page 130).
134
IP address assignment for a SIMOTION D4x5-2
Use case
Insert SIMOTION device or
HW Config
D4x5-2 as delivered
Insert SIMOTION device or
HW Config
D4x5-2 DP as delivered
Insert SIMOTION device or
HW Config
D4x5-2 as delivered
Default address
IP address:
Subnet mask:
Router address:
Automatic private IP
address
IP address:
Subnet mask:
Router address:
Automatic private IP
address
IP address:
Subnet mask:
Router address:
IP address:
Subnet mask:
Router address:
Automatic private IP
address
IP address:
Subnet mask:
Router address:
IP address:
Subnet mask:
Router address:
Commissioning and Hardware Installation Manual, 02/2012
169.254.11.22
255.255.0.0
0.0.0.0
169.254.11.22
255.255.0.0
0.0.0.0
192.168.213.1
255.255.255.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
192.168.2.1
255.255.255.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
SIMOTION D4x5-2