6. The communication for the control of the infeed is configured in the following dialog box.
Figure 6-6
Configuring the process data exchange for the infeed
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
It is recommended that these settings be made automatically by the engineering system.
You can also make the settings manually for the process data exchange by selecting
"User-defined".
If the automatic communication setting has been selected, SIMOTION SCOUT uses
PROFIdrive message frame 370 per default. This message frame is also used by the
system function _LineModule_control to control the infeed.
You can find further information on control of the infeed in Section Activating the infeed
(line module) (Page 239).
If you are using a CX32-2 controller extension, also refer to the information in Section
Interconnecting the infeed "Operation" signal on the CX32-2 (Page 204).
6.2 Performing the configuration for the D4x5-2 offline
Commissioning (software)
167