Diagnostics
8.2 Diagnostic data and non-volatile SIMOTION data
Service selector switch (alternative)
To back up diagnostics data and non-volatile SIMOTION data using a Service selector
switch, proceed as follows:
1. Set the Service selector switch to "Diagnostics" (position "D").
2. The diagnostics data and non-volatile SIMOTION data is backed up to the CompactFlash
3. Once the backup is complete, switch the D4x5-2 off.
4. Remove the CompactFlash card and reset the Service selector switch to its original
Table 8- 9
Status
Backup in progress
Backup complete
362
The positions of the mode selector switch are not relevant (i.e. the set operating mode
remains unchanged).
The diagnostics data and non-volatile SIMOTION data can be created in STOP, STOPU
and RUN states.
Figure 8-4
Service switch and mode selector switch
card.
The backup procedure is displayed via the status LEDs as in the table below.
setting.
LED displays during backup procedure
LED displays on the D4x5-2
STOP LED and SU/PF LED flicker yellow
RUN LED flickers green
Commissioning and Hardware Installation Manual, 02/2012
SIMOTION D4x5-2