Commissioning (software)
6.22 Migration of SIMOTION D4x5 to SIMOTION D4x5-2
6.22.2

Permissible combinations

DRIVE-CLiQ components
Some "older" DRIVE-CLiQ components can no longer be used with the SIMOTION
D4x5-2/CX32-2.
Table 6- 20
DRIVE-CLiQ components
Single motor modules (SMM)
Double motor modules (DMM)
Line modules (ALM/SLM)
Chassis power units
(line modules, motor modules, power
modules)
SMC30 sensor modules cabinet
TM31/TM41 terminal modules
SME20/25 sensor modules external
CUA31 Control Unit adapter
Power modules (chassis)
A detailed, regularly updated list of the DRIVE-CLiQ components approved for use with
SIMOTION, as well as notes on their use, can be found on the Internet at
(http://support.automation.siemens.com/WW/view/en/11886029).
If incorrect components are used, a topology error is signaled
F01360 Topology: Actual topology not permitted.
CX32-2
The tables below provide an overview of the possible combinations:
Table 6- 21
Controller extension
CX32
CX32-2
Only approved combinations can be configured. If physically an incorrect controller extension
is used, a topology error is signaled.
F01360 Topology: Actual topology not permitted
306
DRIVE-CLiQ components that cannot be used with the D4x5-2/CX32-2
Controller extension combinations
Order number
6SL3040-0NA00-0AA0
6AU1432-2AA00-0AA0
Information
6SL31*
(all booksize compact motor modules
6SL34* can be used)
6SL313*
The following can generally be used:
All BLM (6SL313*)
SLM (6SL313*) 5 and 10 kW
Use in D4x5
Possible
Not possible
Commissioning and Hardware Installation Manual, 02/2012
Ending of the
order no.
< 3
< 3
< 3
< 2
< 1
< 3
< 1
< 3
Use in D4x5-2
Not possible
Possible
SIMOTION D4x5-2