Siemens SIMOTION D4 5-2 Series Commissioning And Hardware Installation Manual page 312

Hide thumbs Also See for SIMOTION D4 5-2 Series:
Table of Contents

Advertisement

Service and maintenance
7.1 Overview
Overview of upgrade options
Action/measure
Examples
Creating backup copy
(project/CompactFlash)
Backing up user data
(backing up variables)
Upgrading a user project to the new
SCOUT version
Platform replacement via
XML export/import
Preparing the device replacement
Device replacement in HW Config
Upgrading technology
packages (TP)
3)
Upgrading device version of
SINAMICS S120 CUs
Upgrading a library
Save/compile project; check
consistency
Run firmware and/or project update
Upgrading the boot loader on the
CompactFlash card
Update - preparatory measures
Upgrade via IT DIAG
Update using the
device update tool
Update via CompactFlash card
Backing up the CompactFlash
card data
Firmware update using a
CompactFlash card
Upgrading SINAMICS
5)
Downloading project to
the target system
not relevant
Alternative: Load the project to the Compact Flash card using a card reader
1)
See SW compatibility list (http://support.automation.siemens.com/WW/view/en/18857317)
2)
The versions of SINAMICS Integrated and Controller Extensions are upgraded automatically in the HW Config
3)
during device replacement
The technology packages are automatically upgraded. If necessary a TP can be specified by the user
4)
SINAMICS components are upgraded/downgraded to the component version of the CompactFlash card. Ensure
5)
that LED codes are observed. After the upgrade it is necessary to switch the device off and on.
Figure 7-1
Overview of upgrade options
312
Upgrading a project
Main
Service pack or
version
hotfix version
V4.1
V4.1 SP2
V4.2
V4.1 SP4
only if
required
The target version (= version of the device into which import
is performed) is also specified when the platform is replaced
4)
4)
Libraries are
version-
dependent
Check whether the new
2)
version requires a new boot
loader
Selecting between the three update methods
1)
relevant
Replacement of the SIMOTION controller
PROFINET
SINAMICS
Device replacement
version
version
D445-2
PN2.1
V2.5
D4x5
V2.6.2
D410 DP
PN2.2
only if required
4)
Only as
required for
external CUs
Libraries can be
device-dependent
Check whether a new device
requires a new boot loader
only possible if valid
firmware is located on the
CompactFlash card
Commissioning and Hardware Installation Manual, 02/2012
Platform replacement
via HW Config
via XML export/import
D455-2
C240
D4x5-2
D410
D410 PN
D445
(S120)
only if required
Libraries can be
device-dependent
2)
only possible if valid
firmware is located on the
CompactFlash card
Activity
affects
D445-2
D445-2
D445
(SM150)
SIMOTION D4x5-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents