Siemens SIMOTION D4 5-2 Series Commissioning And Hardware Installation Manual page 304

Hide thumbs Also See for SIMOTION D4 5-2 Series:
Table of Contents

Advertisement

Commissioning (software)
6.22 Migration of SIMOTION D4x5 to SIMOTION D4x5-2
Keyword
Configuration of the
onboard I/Os
CompactFlash card /
firmware
Mixture of Control Units of
different generations
Connectable drive
components
304
Explanation
The configuration of the onboard I/Os is retained. Functionality, quantity structure and
terminal designations of the onboard I/Os for the D4x5-2/CX32-2 differ from the previous
modules because of innovations. Example:
D4x5-2 has additional technology I/Os on terminal block X142 (e.g. for high-precision
cam outputs); a cam output on X122/X132 is no longer supported
Terminal blocks X122/X132 have additional digital inputs and therefore the pin
assignments on the terminal block have been moved.
SIMOTION D4x5 and D4x5-2 have different CompactFlash cards and different card
mappers (firmware).
1 GB CompactFlash cards of the D4x5 can also be used for the D4x5-2 when a new boot
loader is loaded. For details, see Section Boot loader on the CompactFlash card (Page 344).
The firmware version of a controller extension (CX) is always identical to the SINAMICS
Integrated. Therefore
The CX32 can only be operated on the D4x5
The CX32-2 can only be operated on the D4x5-2
These dependencies do not apply for SINAMICS S120 Control Units.
A CU320 can therefore be operated on a D4x5-2.
As for the CU320-2, some older drive components are also no longer supported by the
D4x5-2/CX32-2.
For details, see Section Permissible combinations (Page 306)
Commissioning and Hardware Installation Manual, 02/2012
SIMOTION D4x5-2