Changing the message frame order
Note: Before the alignment, all drive objects without I/O addresses ("---..---") must be moved behind the
objects with valid I/O addresses or those still to be aligned ("???..???").
"Manual" adaptation of the message frame configuration (e.g. when additional data, such as a motor
temperature, is to be transferred via the message frame).
Display of the individual control and status words of the associated message frame.
Setting up the addresses (alignment of the addresses with HW Config)
Only the addresses for the respective drive unit are determined (no automatic determination of message
frames / BICO interconnections).
Note
If symbolic assignment is deactivated, the following applies:
If the message frames for drive objects (drives, terminal modules, etc.) change, you must set
up the addresses again. The addresses are not updated automatically.
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
Commissioning (software)
6.9 Setting up addresses and message frames