CAUTION: Use a 2-pole circuit breaker rated at 25 A in the building installation and the
system, or according to the local electrical code.
Table 11: DIP Switch Settings for JNP10K-PWR-AC2 Power Supplies
INP0 (Switch 1)
On
On
On
Off
On
Off
CAUTION: It is important to connect both input feeds of the JNP10K-PWR-AC2 power
supply to the main AC power before loading the system with power.

JNP10K-PWR-AC2 Power Specifications

The JNP10K-PWR-AC2 power supply supports AC, high-voltage alternating current (HVAC) and high-
voltage direct current (HVDC).
Table 12 on page 41
lists the power specifications for the AC power supply (JNP10K-PWR-AC2) used
in an MX10004 chassis.
INP1 (Switch 2)
On
On
Off
On
Off
On
H/L (High Input 30 A/
Low Input 20 A)
On (30 A)
Off (20 A)
On (30 A)
On (30 A)
Off (20 A)
Off (20 A)
Output Power
5500 W
3000 W
5000 W
5000 W
2700 W
2700 W
40