Juniper SRX300 Series User Manual

Juniper SRX300 Series User Manual

High memory gateway interface modules reference
Hide thumbs Also See for SRX300 Series:
Table of Contents

Advertisement

Quick Links

SRX300 Series and SRX550 High Memory
Gateway Interface Modules Reference
Modified: 2017-08-14
Copyright © 2017, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Juniper SRX300 Series

  • Page 1 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Modified: 2017-08-14 Copyright © 2017, Juniper Networks, Inc.
  • Page 2 END USER LICENSE AGREEMENT The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at http://www.juniper.net/support/eula/.
  • Page 3: Table Of Contents

    Physical Interface Modules Overview ....... . 4 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways .
  • Page 4 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference 1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) Supported Loopback Diagnostics ..........21 1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) Network Interface Specifications .
  • Page 5 Required Tools and Parts for Replacing Interface Modules ....93 Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway ........94...
  • Page 6 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Chapter 14 Replacing Mini-Physical Interface Modules ......95 Replacing Mini-Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways .
  • Page 7 Figure 15: Mounting the Antennas on a Wall ......80 Copyright © 2017, Juniper Networks, Inc.
  • Page 8 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Part 5 Replacing Interface Modules Chapter 13 Overview of Replacing Interface Modules ......93 Figure 16: Placing a Component into an Electrostatic Bag .
  • Page 9 Table 8: MTU Terms ..........9 Table 9: MTU Values for the SRX300 Series and SRX550 High Memory PIMs ..9 Table 10: MTU Values for VDSL- Mini-PIM AT mode (Encapsulation) .
  • Page 10 Serial Mini-Physical Interface Module Cable Specifications ... . . 53 Table 40: Juniper Networks Serial Cables ....... . 53 Table 41: EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-PIM .
  • Page 11 List of Tables Table 53: Return Procedure for SRX Series Services Gateways Component ..106 Copyright © 2017, Juniper Networks, Inc.
  • Page 12 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 13: About The Documentation

    ® To obtain the most current version of all Juniper Networks technical documentation, see the product documentation page on the Juniper Networks website at http://www.juniper.net/techpubs/ If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
  • Page 14: Table 1: Notice Icons

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 1: Notice Icons Icon Meaning Description Informational note Indicates important features or instructions. Caution Indicates a situation that might result in loss of data or hardware damage. Warning Alerts you to the risk of personal injury or death.
  • Page 15: Documentation Feedback

    We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods: Online feedback rating system—On any page of the Juniper Networks TechLibrary site , simply click the stars to rate the content, http://www.juniper.net/techpubs/index.html and use the pop-up form to provide us with information about your experience.
  • Page 16: Requesting Technical Support

    7 days a week, 365 days a year. Self-Help Online Tools and Resources For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features: Find CSC offerings: http://www.juniper.net/customers/support/...
  • Page 17 About the Documentation For international or direct-dial options in countries without toll-free numbers, see http://www.juniper.net/support/requesting-support.html Copyright © 2017, Juniper Networks, Inc. xvii...
  • Page 18 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference xviii Copyright © 2017, Juniper Networks, Inc.
  • Page 19: Overview

    PART 1 Overview SRX Series Services Gateway Interface Modules Support on page 3 Copyright © 2017, Juniper Networks, Inc.
  • Page 20 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 21: Srx Series Services Gateway Interface Modules Support

    SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 4 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 SRX300 Series and SRX550 High Memory Services Gateway Interface Modules and...
  • Page 22: Srx300 Series And Srx550 High Memory Services Gateway Mini-Physical Interface Modules Overview

    Related MTU Default and Maximum Values for Physical Interface Modules on page 8 Documentation SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and Heat Requirements on page 12 SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview...
  • Page 23: Figure 1: Srx550 High Memory Services Gateway Slot Numbers

    Single-high, single-wide LAN switch GPIM that uses one slot Double-high, single-wide LAN switch GPIM that uses two standard slots vertically NOTE: GPIMs are not supported on the SRX300 Series devices. Table 4 on page 5 lists the GPIMs and XPIMs and their respective model numbers.
  • Page 24: Interfaces Port Naming Conventions For The Srx300 Series And Srx550 High Memory Services Gateways

    SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and Heat Requirements on page 12 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory...
  • Page 25: Srx300 Series And Srx550 High Memory Services Gateway Interface Modules And Compatibility

    Modules Overview on page 4 SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 4 SRX300 Series and SRX550 High Memory Services Gateway Interface Modules and Compatibility Table 6 on page 8 shows the types of Mini-Physical Interface Modules (Mini-PIMs) with the SRX Series devices and the Junos OS releases that support them.
  • Page 26: Mtu Default And Maximum Values For Physical Interface Modules

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 6: Mini-PIM Types and Hardware Platform Compatibility Supported Platforms and the First Junos OS Release Supported SRX550 High Name SRX300 SRX320 SRX340 SRX345 Memory Serial Not supported Junos OS...
  • Page 27: Table 8: Mtu Terms

    Table 9 on page 9 lists the MTU values for the SRX300 Series and SRX550 High Memory Services Gateway Physical Interface Modules (PIMs). Table 9: MTU Values for the SRX300 Series and SRX550 High Memory...
  • Page 28: Power Over Ethernet Support On Srx550 High Memory Services Gateway Interfaces

    SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 4 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and...
  • Page 29: Table 11: Poe Specifications For The Srx550 High Memory Services Gateway

    SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Documentation Physical Interface Modules Overview on page 4 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 SRX300 Series and SRX550 High Memory Services Gateway Interface Modules and Compatibility on page 7 Copyright ©...
  • Page 30: Srx300 Series And Srx550 High Memory Services Gateway Interfaces Power And Heat Requirements

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and Heat Requirements Table 12 on page 12 shows the power consumption values of each Physical Interface Module (PIM). Table 12: PIM Power Consumption Values...
  • Page 31: Interface Module Descriptions

    1-Port T1/E1 Mini-Physical (SRX-MP-1T1E1-R) Interface Module on page 19 1-Port VDSL2 Annex A Mini-Physical Interface Module on page 25 8-Port Gigabit Ethernet SFP XPIM on page 29 16-Port Gigabit Ethernet XPIM (PoE) on page 35 LTE Mini-Physical Interface Module on page 39 Copyright © 2017, Juniper Networks, Inc.
  • Page 32 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 33: 1-Port Serial Mini-Physical (Srx-Mp-1Serial-R) Interface Module

    Autoselection of operational modes based on DTE or DCE cables Local and remote loopback diagnostics Configurable clock rate for the transmit (TX) clock and receive (RX) clock Complete configuration and management by using the CLI and the J-Web interface Copyright © 2017, Juniper Networks, Inc.
  • Page 34: 1-Port Serial Mini-Physical Interface Module (Srx-Mp-1Serial-R) Hardware

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference The 1-Port Serial Mini-Physical Interface Module (Mini-PIM) supports the following standards: TIA/EIA 530 V.35 X.21 RS-232 RS-449 Related 1-Port Serial Mini-Physical Interface Module (SRX-MP-1SERIAL-R) Hardware Documentation Specifications on page 16...
  • Page 35: Table 14: 1-Port Serial Mini-Pim (Srx-Mp-1Serial-R) Led States

    Online with no alarms or failures. Device has detected a failure. Related 1-Port Serial Mini-Physical Interface Module (SRX-MP-1SERIAL-R) Overview on page 15 Documentation 1-Port Serial Mini-Physical Interface Module (SRX-MP-1SERIAL-R) Hardware Specifications on page 16 Copyright © 2017, Juniper Networks, Inc.
  • Page 36 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 37: 1-Port T1/E1 Mini-Physical (Srx-Mp-1T1E1-R) Interface Module

    Front Panel The 1-Port T1/E1 Mini-Physical Interface Module (Mini-PIM) provides the following key features: Channel service unit/data service unit (CSU/DSU) to eliminate the need for a separate external device 56-Kbps and 64-Kbps operating modes Copyright © 2017, Juniper Networks, Inc.
  • Page 38: Specifications

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Independent internal and external clocking option Alarm reporting with a 24-hour history maintained Loopback, BERT, FDL (T1 only), and Long Buildout (T1 only) diagnostics Multilink Frame Relay and Multilink PPP support...
  • Page 39: 1-Port T1/E1 Mini-Physical Interface Module (Srx-Mp-1T1E1-R) Leds

    Specifications on page 22 1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) Supported Loopback Diagnostics The 1-Port T1/E1 Mini-Physical Interface Module (Mini-PIM) has the following loopback diagnostics: Local, remote, payload Test patterns (BERT) All ones All zeros Copyright © 2017, Juniper Networks, Inc.
  • Page 40: Specifications

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Alternating ones and zeros (AA/55) 1:3 or 1-in-4 pattern 1:7 or 1-in-8 pattern 3:24 - 3 bits set in every 24 bits QRSS20 (Modified PRBS 2^20-1, with 14 zero suppression) PRBS 2^7-1 - PRBS 2^9-1 (as specified in ITU-T O.153)
  • Page 41 Documentation 1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) Hardware Specifications on page 20 1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) LEDs on page 21 1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) Supported Loopback Diagnostics on page 21 Copyright © 2017, Juniper Networks, Inc.
  • Page 42 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 43: 1-Port Vdsl2 Annex A Mini-Physical Interface Module

    The 1-Port VDSL2 Annex A Mini-PIM is compatible with the ITU-T G.993.2 (VDSL2) standard. Figure 6 on page 25 shows the 1-Port VDSL2 Annex A (SRX-MP-1VDSL2-R) Mini-PIM. Figure 6: VDSL2 Annex A (SRX-MP-1VDSL2-R) Mini-PIM Copyright © 2017, Juniper Networks, Inc.
  • Page 44: 1-Port Vdsl2 Annex A Mini-Physical Interface Module (Srx-Mp-1Vdsl2-R) Hardware Specifications

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference The following features are supported on the 1-Port VDSL2 Annex A Mini-Physical Interface Module (Mini-PIM): ADSL/ADSL2/ADSL2+ backward compatibility with Annex-A, Annex-M support Packet Mode Transfer (PTM) or Ethernet in the First Mile (EFM) (802.3ah) support...
  • Page 45: Leds

    A profile is a table that contains a list of preconfigured VDSL2 settings. Table 20 on page 28 lists the different profiles supported on the 1-Port VDSL2 Annex A Mini-PIM, along with their data rates. Copyright © 2017, Juniper Networks, Inc.
  • Page 46: Table 20: Supported Profiles On The 1-Port Vdsl2 Annex A (Srx-Mp-1Vdsl2-R)

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 20: Supported Profiles on the 1-Port VDSL2 Annex A (SRX-MP-1VDSL2-R) Mini-PIM Profiles Data Rate Auto Auto mode (default) Related 1-Port VDSL2 Annex A Mini-Physical Interface Module (SRX-MP-1VDSL2-R) Overview Documentation...
  • Page 47: 8-Port Gigabit Ethernet Sfp Xpim

    Figure 7: 8-Port Gigabit Ethernet SFP XPIM Front Panel The 8-Port Gigabit Ethernet small form-factor pluggable XPIM (SFP XPIM) has the following key features: 8 triple-speed (10/100/1000 Mbps) Ethernet ports, single-high card PoE not supported PCI-Express interface for control and management Copyright © 2017, Juniper Networks, Inc.
  • Page 48: 8-Port Gigabit Ethernet Sfp Xpim Components

    (JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
  • Page 49: 8-Port Gigabit Ethernet Sfp Xpim Hardware Specifications

    — LINK and ACT. Each XPIM has a STATUS LED, which indicates the status of the XPIM. The LEDs are listed in Table 23 on page 32. See “8-Port Gigabit Ethernet SFP XPIM Overview” on page 29 for more information. Copyright © 2017, Juniper Networks, Inc.
  • Page 50: 8-Port Gigabit Ethernet Sfp Xpim Supported Transceivers

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 23: 8-Port Gigabit Ethernet SFP XPIM LED States Color State Description LINK Green Port is online. Port is offline. Green Blinking Port is receiving or sending data. Port might be online, but is not receiving or sending data.
  • Page 51 (JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
  • Page 52: 8-Port Gigabit Ethernet Sfp Xpim Network Interface Specifications

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference 8-Port Gigabit Ethernet SFP XPIM Network Interface Specifications Table 25 on page 34 provides the network interface specifications of the 8-Port Gigabit Ethernet small form-factor pluggable XPIM (SFP XPIM). Table 25: 8-Port Gigabit Ethernet SFP XPIM Network Interface...
  • Page 53: 16-Port Gigabit Ethernet Xpim (Poe)

    6 of the SRX550 High Memory Services Gateway. However, the performance (bandwidth) in slot 3 will be limited as it has a 10G back link. NOTE: The SRX550 High Memory Services Gateway does not support hot-swappable functionality for GPIMs. Copyright © 2017, Juniper Networks, Inc.
  • Page 54: 16-Port Gigabit Ethernet Xpim (Poe) Components

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Figure 8: 16-Port Gigabit Ethernet with PoE XPIM The 16-Port Gigabit Ethernet XPIM has the following key features: 16 triple-speed (10/100/1000 Mbps) Ethernet ports, double-high card PoE support for all ports...
  • Page 55: 16-Port Gigabit Ethernet Xpim (Poe) Hardware Specifications

    16-Port Gigabit Ethernet XPIM (PoE) Components on page 36 16-Port Gigabit Ethernet XPIM (PoE) LEDs on page 37 16-Port Gigabit Ethernet XPIM (PoE) LEDs Table 28 on page 38 lists the LEDs on the 16-Port Gigabit Ethernet XPIM. Copyright © 2017, Juniper Networks, Inc.
  • Page 56: Table 28: 16-Port Gigabit Ethernet Xpim Led States

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 28: 16-Port Gigabit Ethernet XPIM LED States Color State Description STATUS Green XPIM is online and functioning normally. Yellow XPIM is starting up, running diagnostics, or shutting down. XPIM has failed.
  • Page 57: Lte Mini-Physical Interface Module

    LTE Mini-Physical Interface Module The LTE Mini-Physical Interface Module (Mini-PIM) provides wireless WAN support on the SRX300 Series and SRX550 High Memory Services Gateways. The Mini-PIM contains an integrated modem and operates over 3G and 4G networks. The Mini-PIM supports up to two SIM cards and can be installed in any of the Mini-PIM slots on the services gateways.
  • Page 58: Table 29: Lte Mini-Pim Front Panel Components

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 29: LTE Mini-PIM Front Panel Components Component Description Antenna connectors Two SubMiniature version A (SMA) connectors. Mini-USB port Mini-USB Type-B port for monitoring and troubleshooting. SIM slots Two slots,...
  • Page 59: Table 31: Antenna Base Specifications

    FCC Part 2 FCC Part 22 FCC Part 24, Part 27 and Part 90 RSS 129 and RSS 133, RSS 130, RSS 199, and RSS 139 RSS 132 and RSS 133 EN 301 511 GSM Copyright © 2017, Juniper Networks, Inc.
  • Page 60: Lte Mini-Physical Interface Module Leds

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference EN 301 908-1 EN 301 908-2 The Certification and Engineering Bureau of Industry Canada (IC) Radio Equipment (RE) Directive of the European Union CTIA-PTCRB Related LTE Mini-Physical Interface Module LEDs on page 42...
  • Page 61: Lte Mini-Physical Interface Module Hardware Specifications

    Storage temperature -40° F through 158° F (-40° C through 70° C) Relative humidity 5% to 90% noncondensing Related LTE Mini-Physical Interface Module on page 39 Documentation LTE Mini-Physical Interface Module LEDs on page 42 Copyright © 2017, Juniper Networks, Inc.
  • Page 62 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 63: Cable Specifications And Pinouts

    PART 3 Cable Specifications and Pinouts T1/E1 Mini-Physical Interface Module on page 47 VDSL2 Mini-Physical Interface Module Cable Specifications on page 51 Serial Mini-Physical Interface Module Cable Specifications on page 53 Copyright © 2017, Juniper Networks, Inc.
  • Page 64 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 65: T1/E1 Mini-Physical Interface Module

    RJ-48 Pin (on 1-Port RJ-48 Pin (Data T1/E1 Mini-PIM) Numbering Form) Signal RX, Ring, – RX, Tip, + TX, Ring, – TX, Tip, + Shield/Return/Ground Shield/Return/Ground No connect No connect No connect No connect Copyright © 2017, Juniper Networks, Inc.
  • Page 66: Connector To Db-15 Connector Pinouts For The 1-Port T1/E1 Mini-Physical Interface Module (Srx-Mp-1T1E1-R)

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 36 on page 48 lists the RJ-48 connector to RJ-48 connector (crossover) pinouts for the 1-Port T1/E1 Mini-Physical Interface Module (Mini-PIM). Table 36: RJ-48 Connector to RJ-48 Connector (Crossover) Pinouts...
  • Page 67: Table 38: Rj-48 Connector To Db-15 Connector (Crossover) Pinouts

    T1/E1 Mini-PIM) Form) Signal RX/Ring/– <––>TX/Ring/– RX/Tip/+ <––>TX/Tip/+ TX/Ring/– <––>RX/Ring/– TX/Tip/+ <––>RX/Tip/+ Shield/Return/Ground Shield/Return/Ground No connect No connect No connect No connect No connect No connect No connect No connect No connect No connect Copyright © 2017, Juniper Networks, Inc.
  • Page 68 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 38: RJ-48 Connector to DB-15 Connector (Crossover) Pinouts (continued) RJ-48 Pin (on DB-15 Pin (Data Numbering T1/E1 Mini-PIM) Form) Signal No connect No connect No connect No connect No connect...
  • Page 69: Vdsl2 Mini-Physical Interface Module Cable Specifications

    Figure 11 on page 51 shows the RJ-11 cable design. Figure 11: RJ-11 Cable Pinout for 1-Port VDSL2 Annex A (SRX-MP-1VDSL2-R) Mini-PIM Table 39 on page 52 shows the pin assignments of the RJ-11 cable. Copyright © 2017, Juniper Networks, Inc.
  • Page 70: Table 39: Rj-11 Cable Pinout Details For 1-Port Vdsl2 Annex A (Srx-Mp-1Vdsl2-R) Mini-Pim

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 39: RJ-11 Cable Pinout Details for 1-Port VDSL2 Annex A (SRX-MP-1VDSL2-R) Mini-PIM Signal Ground RX (data input) Tx (data output) Vcc (power) Related 1-Port VDSL2 Annex A Mini-Physical Interface Module (SRX-MP-1VDSL2-R) Overview...
  • Page 71: Serial Mini-Physical Interface Module Cable Specifications

    1-Port Serial Mini-Physical Interface Module Interface Cables Table 40 on page 53 lists the cables that you can order from Juniper Networks to connect to a port on the synchronous 1-Port Serial Mini-Physical Interface Module (Mini-PIM). The device to which you are connecting and the serial interface types determine which type of cable you need.
  • Page 72: Module

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 40: Juniper Networks Serial Cables (continued) Connector Product Number Interface Type Length Type JX-CBL-EIA530-DTE EIA530 cable (DTE) 3.04 m (10 ft) Male JX-CBL-RS232-DCE RS232 cable (DCE) 3.04 m (10 ft)
  • Page 73: Table 41: Eia-530A Dce Cable Pinouts For The 1-Port Serial Mini-Pim

    Clear to Send (B) Transmit Data (B) Transmit Clock (A) Receive Data (B) Receive Clock (A) Local Loopback Request to Send (B) Data Terminal Ready (A) Signal Ground Terminal Timing (A) 26 to 25 Copyright © 2017, Juniper Networks, Inc.
  • Page 74: Table 42: Eia-530A Dte Cable Pinouts For The 1-Port Serial Mini-Pim

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 41: EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) LFH-60 LFH-60 Pin DB-25 Pin Pairing Description 30 to 29 Related RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on...
  • Page 75: Module

    X.21 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 66 RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module Table 43 on page 58 gives the RS-232 DCE cable pinouts. Copyright © 2017, Juniper Networks, Inc.
  • Page 76: Table 43: Rs-232 Dce Cable Pinouts For The 1-Port Serial Mini-Pim

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 43: RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-PIM LFH-60 LFH-60 Pin DB-25 Pin Pairing Description Frame Ground Transmit Data Receive Data Request to Send Clear to Send...
  • Page 77: Table 44: Rs-232 Dte Cable Pinouts For The 1-Port Serial Mini-Pim

    X.21 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 66 RS-422/449 (EIA-449) DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module Table 45 on page 60 gives the RS-422/449 DCE cable pinouts. Copyright © 2017, Juniper Networks, Inc.
  • Page 78: Table 45: Rs-422/449 Dce Cable Pinouts For The 1-Port Serial Mini-Pim

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 45: RS-422/449 DCE Cable Pinouts for the 1-Port Serial Mini-PIM DC-37 LFH-60 LFH-60 Pin (DB-37) Pin Pairing Description Shield Ground Send Data (A) Send Timing (A) Receive Data (A)
  • Page 79: Table 46: Rs-422/449 Dte Cable Pinouts For The 1-Port Serial Mini-Pim

    (DB-37) Pin Pairing Description Shield Ground Send Data (A) Send Timing (A) Receive Data (A) Request to Send (A) Receive Timing (A) Clear to Send (A) Local Loopback Data Mode (A) Terminal Ready (A) Copyright © 2017, Juniper Networks, Inc.
  • Page 80 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 46: RS-422/449 DTE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) DC-37 LFH-60 LFH-60 Pin (DB-37) Pin Pairing Description Receive Ready (A) Terminal Timing (A) Signal Ground Receive Common...
  • Page 81: Dce Cable Pinouts For The 1-Port Serial Mini-Physical Interface Module

    Transmit Data (A) Receive Data (A) Transmit Data (B) Receive Data (B) Terminal Timing (A) Receive Timing (A) Terminal Timing (B) Receive Timing (B) Transmit Timing (A) Transmit Timing (B) 22 to 21 26 to 25 Copyright © 2017, Juniper Networks, Inc.
  • Page 82: Dte Cable Pinouts For The 1-Port Serial Mini-Physical Interface Module

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Related EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on Documentation page 54 RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 57...
  • Page 83: X.21 Dce Cable Pinouts For The 1-Port Serial Mini-Physical Interface Module

    Table 49: X.21 DCE Cable Pinouts for the 1-Port Serial Mini-PIM LFH-60 Pin DB-15 Pin LFH-60 Pairing Description Shield Ground Transmit Data (A) Control (A) Receive (A) Indicate (A) Signal Element Timing (A) Signal Ground Transmit Data (B) Copyright © 2017, Juniper Networks, Inc.
  • Page 84: Dte Cable Pinouts For The 1-Port Serial Mini-Physical Interface Module

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 49: X.21 DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) LFH-60 Pin DB-15 Pin LFH-60 Pairing Description Control (B) Receive (B) Indicate (B) Signal Element Timing (B) 30 to 29...
  • Page 85 RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 58 RS-422/449 (EIA-449) DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 61 V.35 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 64 Copyright © 2017, Juniper Networks, Inc.
  • Page 86 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 87: Configuration

    PART 4 Configuration Configuring Mini-Physical Interface Modules on page 71 Configuring Gigabit-Backplane Physical Interface Modules on page 87 Copyright © 2017, Juniper Networks, Inc.
  • Page 88 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 89: Configuring Mini-Physical Interface Modules

    . To use the port on the Mini-PIM, assign an IP address to the port and assign it to a security zone, other than the Null zone. If there are no security zones listed, proceed to the next step to add a security zone. Copyright © 2017, Juniper Networks, Inc.
  • Page 90: Using The Cli

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Add a security zone to the interface: Select Configure>Security>Zones/Screens Add or select a security zone other than Null; for example, . Assign the interface Trust to the zone. For Host Inbound Traffic-Zone, set the following:...
  • Page 91: Configuration

    Add a security zone to the interface: Select Configure>Security>Zones/Screens Add or select a security zone other than Null; for example, . Assign the interface Trust to the zone. For Host Inbound Traffic-Zone, set the following: System Services= Allow All Copyright © 2017, Juniper Networks, Inc.
  • Page 92: Using The Cli

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Protocols= Allow All Click to save changes, and select to apply the configuration Commit>Commit and other pending changes (if any). To use the port on the Mini-PIM, you must also set security policies. Select the following...
  • Page 93: 1-Port Vdsl2 Annex A Mini-Physical Interface Module (Srx-Mp-1Vdsl2-R) Basic Configuration

    . To use the port on the Mini-PIM, assign an IP address to the port and assign it to a security zone, other than the Null zone. If there are no security zones listed, proceed to the next step to add a security zone. Copyright © 2017, Juniper Networks, Inc.
  • Page 94: Using The Cli

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Add a security zone to the interface: Select Configure>Security>Zones/Screens Add or select a security zone other than Null; for example, . Assign the interface Trust to the zone. For Host Inbound Traffic-Zone, set the following:...
  • Page 95: Lte Mini-Physical Interface Module Installation And Configuration

    Grasp the screws on each side of the Mini-PIM faceplate and align the notches in the connector at the rear of the Mini-PIM with the notches in the Mini-PIM slot in the services gateway. Copyright © 2017, Juniper Networks, Inc.
  • Page 96: Figure 12: Installing The Lte Mini-Pim

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference CAUTION: Slide the Mini-PIM straight into the slot to avoid damaging the components on the Mini-PIM. Slide the Mini-PIM in until it lodges firmly in the services gateway. See Figure 12 on page Figure 12: Installing the LTE Mini-PIM Using a 1/8-in.
  • Page 97: Figure 13: Attaching The Antennas

    The antenna base is magnetic and can be attached to the rack directly, if the rack is metallic. Else, you can mount the antenna base on the rack using the mounting brackets. See Figure 14 on page Figure 14: Mounting the Antennas on a Rack Copyright © 2017, Juniper Networks, Inc.
  • Page 98: Configuring The Lte Mini-Pim

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference NOTE: For SRX320 Services Gateways, which can be mounted on a wall, the antennas can be mounted as shown in Figure 15 on page Figure 15: Mounting the Antennas on a Wall >...
  • Page 99 0 family inet6 negotiate-address user@host# set interfaces dl0 unit 0 family inet filter dialer dialer-filter-name user@host# set interfaces dl0 unit 0 dialer-options pool dialer-pool-number user@host# set interfaces dl0 unit 0 dialer-options dial-string dial-number Backup mode: Copyright © 2017, Juniper Networks, Inc.
  • Page 100: Firmware Upgrade On The Lte Mini-Physical Interface Module

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference user@host# set interfaces dl0 unit 0 family inet negotiate-address user@host# set interfaces dl0 unit 0 family inet6 negotiate-address user@host# set interfaces dl0 unit 0 dialer-options pool dialer-pool-number user@host# set interfaces dl0 unit 0 dialer-options dial-string dial-number user@host# set interfaces interface-name unit 0 backup-options interface dl0.0...
  • Page 101 Slot 0 Online PIC 0 Online 6xGE,2xGE SFP Base PIC Slot 1 Online PIC 0 Online MLTE AA PIC Verify that the firmware is upgraded to the latest version: user@host > show system firmware Copyright © 2017, Juniper Networks, Inc.
  • Page 102: Modem Firmware Upgrade Through Over-The-Air (Ota)

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Modem Firmware Upgrade Through Over-the-Air (OTA) Over-the-Air (OTA) firmware upgrade enables automatic and timely upgrade of modem firmware when new firmware versions are available. The OTA upgrade can be enabled or disabled on the 4G/LTE Mini-PIM.
  • Page 103 Reference Signal Receiving Quality (RSRQ): -16 Signal to Interference-plus-Noise Ratio (SiNR): 0 Signal Noise Ratio (SNR): 0 Energy per Chip to Interference (ECIO): 0 Related LTE Mini-Physical Interface Module Installation and Configuration on page 77 Documentation Copyright © 2017, Juniper Networks, Inc.
  • Page 104 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 105: Configuring Gigabit-Backplane Physical Interface Modules

    CHAPTER 12 Configuring Gigabit-Backplane Physical Interface Modules 8-Port Gigabit Ethernet SFP XPIM Basic Configuration on page 88 16-Port Gigabit Ethernet XPIM Basic Configuration on page 89 Copyright © 2017, Juniper Networks, Inc.
  • Page 106: 8-Port Gigabit Ethernet Sfp Xpim Basic Configuration

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference 8-Port Gigabit Ethernet SFP XPIM Basic Configuration The 8-Port Gigabit Ethernet small form-factor pluggable Gigabit-Backplane Physical Interface Module (SFP XPIM) provides connectivity to a single Gigabit Ethernet device or to a network. After you install the XPIM in the services gateway, you configure a network interface on the XPIM.
  • Page 107: 16-Port Gigabit Ethernet Xpim Basic Configuration

    CLI configuration editor. In addition, you can configure a wider variety of options that are encountered less frequently. Related 16-Port Gigabit Ethernet XPIM (PoE) Overview on page 35 Documentation 16-Port Gigabit Ethernet XPIM (PoE) Components on page 36 Copyright © 2017, Juniper Networks, Inc.
  • Page 108 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference 16-Port Gigabit Ethernet XPIM (PoE) Hardware Specifications on page 37 16-Port Gigabit Ethernet XPIM (PoE) LEDs on page 37 Copyright © 2017, Juniper Networks, Inc.
  • Page 109: Replacing Interface Modules

    Replacing Interface Modules Overview of Replacing Interface Modules on page 93 Replacing Mini-Physical Interface Modules on page 95 Replacing Gigabit-Backplane Physical Interface Modules on page 99 Contacting Customer Support and Returning Components on page 105 Copyright © 2017, Juniper Networks, Inc.
  • Page 110 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 111: Overview Of Replacing Interface Modules

    Overview of Replacing Interface Modules Required Tools and Parts for Replacing Interface Modules on page 93 Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway on page 94 Required Tools and Parts for Replacing Interface Modules...
  • Page 112: Preventing Electrostatic Discharge Damage To The Srx300 Series And Srx550 High Memory Services Gateway

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway Many services gateway hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets.
  • Page 113: Replacing Mini-Physical Interface Modules

    CHAPTER 14 Replacing Mini-Physical Interface Modules Replacing Mini-Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways on page 95 Replacing Mini-Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways Before you begin, power off the services gateway.
  • Page 114: Installing A Mini-Physical Interface Module

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Unplug the power adapter from the services gateway. Verify that the Power LED is off. Label the cables connected to the Mini-PIM so that you can later reconnect each cable to the correct Mini-PIM.
  • Page 115: Removing A Blank Mini-Physical Interface Module Faceplate

    Align the captive screws on the blank faceplate with the screw holes on the chassis. Tighten the screws on each side of the faceplate. On faceplates with handles, use a 1/8-in. (3-mm) flat-blade (–) screwdriver to tighten the captive screws. Copyright © 2017, Juniper Networks, Inc.
  • Page 116 On faceplates without handles, use a Phillips number 1 screwdriver to tighten the noncaptive screws. Related Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Documentation Memory Services Gateway on page 94 SRX300 Series and SRX550 High Memory Services Gateway Mini-Physical Interface Modules Overview on page 4 Copyright ©...
  • Page 117: Replacing Gigabit-Backplane Physical Interface Modules

    CHAPTER 15 Replacing Gigabit-Backplane Physical Interface Modules Replacing Gigabit-Backplane Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways on page 99 Replacing Gigabit-Backplane Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways...
  • Page 118: Installing A Gigabit-Backplane Physical Interface Module

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 51: LED Indications for Hot-Swappable GPIM Components (continued) Number Component Description ONLINE/OFFLINE Push the button to turn the GPIM offline. After the STATUS button LED light goes off, it is safe to remove the GPIM from the services gateway.
  • Page 119 Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, “Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway” on page Grasp the handles on each side of the GPIM faceplate, and align the edges of the GPIM circuit board with the guide rails at each side of the GPIM slot.
  • Page 120: Faceplate

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 52: Hot-Swappable Component Descriptions for GPIMs Number Component Description STATUS LED The STATUS LED has the following indicator s: Steady green indicates that the GPIM is functioning normally. Steady yellow indicates that the GPIM is starting up, running diagnostics, or going offline.
  • Page 121 Chapter 15: Replacing Gigabit-Backplane Physical Interface Modules Related SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Documentation Physical Interface Modules Overview on page 4 Copyright © 2017, Juniper Networks, Inc.
  • Page 122 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.
  • Page 123: Contacting Customer Support And Returning Components

    Contacting Customer Support Once you have located the serial numbers of the services gateway or component, you can return them for repair or replacement. For this, you need to contact Juniper Networks Technical Assistance Center (JTAC). You can contact JTAC 24 hours a day, 7 days a week, using any of the following methods: On the Web: Using the Case Manager link at http://www.juniper.net/support/...
  • Page 124: Return Procedure For Srx Series Services Gateway Hardware Components

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Locating the SRX Series Services Gateway Hardware Component Mini-PIM or GPIM Serial Number Label on page 107 Information You Might Need to Supply to JTAC on page 107 Packing the SRX Series Services Gateway Hardware Components for Shipment on...
  • Page 125: Locating The Srx Series Services Gateway Hardware Component Mini-Pim Or Gpim Serial Number Label

    Contacting Customer Support on page 105 Information You Might Need to Supply to JTAC If you are returning a hardware component to Juniper Networks for repair or replacement, obtain a Return Materials Authorization (RMA) number from Juniper Networks Technical Assistance Center (JTAC).
  • Page 126: Required Tools And Parts For Packing The Srx Series Services Gateway Hardware Components

    SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Configuration data displayed by one or more commands show Your name, organization name, telephone number, fax number, and shipping address Related Return Procedure for SRX Series Services Gateway Hardware Components on page 106...
  • Page 127 Return Procedure for SRX Series Services Gateway Hardware Components on page 106 Documentation Locating the SRX Series Services Gateway Hardware Component Mini-PIM or GPIM Serial Number Label on page 107 Information You Might Need to Supply to JTAC on page 107 Copyright © 2017, Juniper Networks, Inc.
  • Page 128 SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Copyright © 2017, Juniper Networks, Inc.

This manual is also suitable for:

Srx550Srx300Srx320Srx340Srx345

Table of Contents