Page 2
END USER LICENSE AGREEMENT The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at http://www.juniper.net/support/eula/.
Page 5
Required Tools and Parts for Replacing Interface Modules ....93 Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway ........94...
Page 6
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Chapter 14 Replacing Mini-Physical Interface Modules ......95 Replacing Mini-Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways .
Page 8
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Part 5 Replacing Interface Modules Chapter 13 Overview of Replacing Interface Modules ......93 Figure 16: Placing a Component into an Electrostatic Bag .
Page 9
Table 8: MTU Terms ..........9 Table 9: MTU Values for the SRX300 Series and SRX550 High Memory PIMs ..9 Table 10: MTU Values for VDSL- Mini-PIM AT mode (Encapsulation) .
Page 10
Serial Mini-Physical Interface Module Cable Specifications ... . . 53 Table 40: Juniper Networks Serial Cables ....... . 53 Table 41: EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-PIM .
® To obtain the most current version of all Juniper Networks technical documentation, see the product documentation page on the Juniper Networks website at http://www.juniper.net/techpubs/ If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 1: Notice Icons Icon Meaning Description Informational note Indicates important features or instructions. Caution Indicates a situation that might result in loss of data or hardware damage. Warning Alerts you to the risk of personal injury or death.
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods: Online feedback rating system—On any page of the Juniper Networks TechLibrary site , simply click the stars to rate the content, http://www.juniper.net/techpubs/index.html and use the pop-up form to provide us with information about your experience.
7 days a week, 365 days a year. Self-Help Online Tools and Resources For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features: Find CSC offerings: http://www.juniper.net/customers/support/...
SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 4 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 SRX300 Series and SRX550 High Memory Services Gateway Interface Modules and...
Related MTU Default and Maximum Values for Physical Interface Modules on page 8 Documentation SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and Heat Requirements on page 12 SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview...
Single-high, single-wide LAN switch GPIM that uses one slot Double-high, single-wide LAN switch GPIM that uses two standard slots vertically NOTE: GPIMs are not supported on the SRX300 Series devices. Table 4 on page 5 lists the GPIMs and XPIMs and their respective model numbers.
SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and Heat Requirements on page 12 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory...
Modules Overview on page 4 SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 4 SRX300 Series and SRX550 High Memory Services Gateway Interface Modules and Compatibility Table 6 on page 8 shows the types of Mini-Physical Interface Modules (Mini-PIMs) with the SRX Series devices and the Junos OS releases that support them.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 6: Mini-PIM Types and Hardware Platform Compatibility Supported Platforms and the First Junos OS Release Supported SRX550 High Name SRX300 SRX320 SRX340 SRX345 Memory Serial Not supported Junos OS...
Table 9 on page 9 lists the MTU values for the SRX300 Series and SRX550 High Memory Services Gateway Physical Interface Modules (PIMs). Table 9: MTU Values for the SRX300 Series and SRX550 High Memory...
SRX300 Series and SRX550 High Memory Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 4 Interfaces Port Naming Conventions for the SRX300 Series and SRX550 High Memory Services Gateways on page 6 SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference SRX300 Series and SRX550 High Memory Services Gateway Interfaces Power and Heat Requirements Table 12 on page 12 shows the power consumption values of each Physical Interface Module (PIM). Table 12: PIM Power Consumption Values...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference The 1-Port Serial Mini-Physical Interface Module (Mini-PIM) supports the following standards: TIA/EIA 530 V.35 X.21 RS-232 RS-449 Related 1-Port Serial Mini-Physical Interface Module (SRX-MP-1SERIAL-R) Hardware Documentation Specifications on page 16...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Independent internal and external clocking option Alarm reporting with a 24-hour history maintained Loopback, BERT, FDL (T1 only), and Long Buildout (T1 only) diagnostics Multilink Frame Relay and Multilink PPP support...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Alternating ones and zeros (AA/55) 1:3 or 1-in-4 pattern 1:7 or 1-in-8 pattern 3:24 - 3 bits set in every 24 bits QRSS20 (Modified PRBS 2^20-1, with 14 zero suppression) PRBS 2^7-1 - PRBS 2^9-1 (as specified in ITU-T O.153)
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference The following features are supported on the 1-Port VDSL2 Annex A Mini-Physical Interface Module (Mini-PIM): ADSL/ADSL2/ADSL2+ backward compatibility with Annex-A, Annex-M support Packet Mode Transfer (PTM) or Ethernet in the First Mile (EFM) (802.3ah) support...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 20: Supported Profiles on the 1-Port VDSL2 Annex A (SRX-MP-1VDSL2-R) Mini-PIM Profiles Data Rate Auto Auto mode (default) Related 1-Port VDSL2 Annex A Mini-Physical Interface Module (SRX-MP-1VDSL2-R) Overview Documentation...
(JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 23: 8-Port Gigabit Ethernet SFP XPIM LED States Color State Description LINK Green Port is online. Port is offline. Green Blinking Port is receiving or sending data. Port might be online, but is not receiving or sending data.
Page 51
(JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Figure 8: 16-Port Gigabit Ethernet with PoE XPIM The 16-Port Gigabit Ethernet XPIM has the following key features: 16 triple-speed (10/100/1000 Mbps) Ethernet ports, double-high card PoE support for all ports...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 28: 16-Port Gigabit Ethernet XPIM LED States Color State Description STATUS Green XPIM is online and functioning normally. Yellow XPIM is starting up, running diagnostics, or shutting down. XPIM has failed.
LTE Mini-Physical Interface Module The LTE Mini-Physical Interface Module (Mini-PIM) provides wireless WAN support on the SRX300 Series and SRX550 High Memory Services Gateways. The Mini-PIM contains an integrated modem and operates over 3G and 4G networks. The Mini-PIM supports up to two SIM cards and can be installed in any of the Mini-PIM slots on the services gateways.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 29: LTE Mini-PIM Front Panel Components Component Description Antenna connectors Two SubMiniature version A (SMA) connectors. Mini-USB port Mini-USB Type-B port for monitoring and troubleshooting. SIM slots Two slots,...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference EN 301 908-1 EN 301 908-2 The Certification and Engineering Bureau of Industry Canada (IC) Radio Equipment (RE) Directive of the European Union CTIA-PTCRB Related LTE Mini-Physical Interface Module LEDs on page 42...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 36 on page 48 lists the RJ-48 connector to RJ-48 connector (crossover) pinouts for the 1-Port T1/E1 Mini-Physical Interface Module (Mini-PIM). Table 36: RJ-48 Connector to RJ-48 Connector (Crossover) Pinouts...
Page 68
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 38: RJ-48 Connector to DB-15 Connector (Crossover) Pinouts (continued) RJ-48 Pin (on DB-15 Pin (Data Numbering T1/E1 Mini-PIM) Form) Signal No connect No connect No connect No connect No connect...
1-Port Serial Mini-Physical Interface Module Interface Cables Table 40 on page 53 lists the cables that you can order from Juniper Networks to connect to a port on the synchronous 1-Port Serial Mini-Physical Interface Module (Mini-PIM). The device to which you are connecting and the serial interface types determine which type of cable you need.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 40: Juniper Networks Serial Cables (continued) Connector Product Number Interface Type Length Type JX-CBL-EIA530-DTE EIA530 cable (DTE) 3.04 m (10 ft) Male JX-CBL-RS232-DCE RS232 cable (DCE) 3.04 m (10 ft)
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 41: EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) LFH-60 LFH-60 Pin DB-25 Pin Pairing Description 30 to 29 Related RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 43: RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-PIM LFH-60 LFH-60 Pin DB-25 Pin Pairing Description Frame Ground Transmit Data Receive Data Request to Send Clear to Send...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 45: RS-422/449 DCE Cable Pinouts for the 1-Port Serial Mini-PIM DC-37 LFH-60 LFH-60 Pin (DB-37) Pin Pairing Description Shield Ground Send Data (A) Send Timing (A) Receive Data (A)
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Related EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on Documentation page 54 RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 57...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 49: X.21 DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) LFH-60 Pin DB-15 Pin LFH-60 Pairing Description Control (B) Receive (B) Indicate (B) Signal Element Timing (B) 30 to 29...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Add a security zone to the interface: Select Configure>Security>Zones/Screens Add or select a security zone other than Null; for example, . Assign the interface Trust to the zone. For Host Inbound Traffic-Zone, set the following:...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Protocols= Allow All Click to save changes, and select to apply the configuration Commit>Commit and other pending changes (if any). To use the port on the Mini-PIM, you must also set security policies. Select the following...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Add a security zone to the interface: Select Configure>Security>Zones/Screens Add or select a security zone other than Null; for example, . Assign the interface Trust to the zone. For Host Inbound Traffic-Zone, set the following:...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference CAUTION: Slide the Mini-PIM straight into the slot to avoid damaging the components on the Mini-PIM. Slide the Mini-PIM in until it lodges firmly in the services gateway. See Figure 12 on page Figure 12: Installing the LTE Mini-PIM Using a 1/8-in.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference NOTE: For SRX320 Services Gateways, which can be mounted on a wall, the antennas can be mounted as shown in Figure 15 on page Figure 15: Mounting the Antennas on a Wall >...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference user@host# set interfaces dl0 unit 0 family inet negotiate-address user@host# set interfaces dl0 unit 0 family inet6 negotiate-address user@host# set interfaces dl0 unit 0 dialer-options pool dialer-pool-number user@host# set interfaces dl0 unit 0 dialer-options dial-string dial-number user@host# set interfaces interface-name unit 0 backup-options interface dl0.0...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Modem Firmware Upgrade Through Over-the-Air (OTA) Over-the-Air (OTA) firmware upgrade enables automatic and timely upgrade of modem firmware when new firmware versions are available. The OTA upgrade can be enabled or disabled on the 4G/LTE Mini-PIM.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference 8-Port Gigabit Ethernet SFP XPIM Basic Configuration The 8-Port Gigabit Ethernet small form-factor pluggable Gigabit-Backplane Physical Interface Module (SFP XPIM) provides connectivity to a single Gigabit Ethernet device or to a network. After you install the XPIM in the services gateway, you configure a network interface on the XPIM.
Overview of Replacing Interface Modules Required Tools and Parts for Replacing Interface Modules on page 93 Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway on page 94 Required Tools and Parts for Replacing Interface Modules...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway Many services gateway hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets.
CHAPTER 14 Replacing Mini-Physical Interface Modules Replacing Mini-Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways on page 95 Replacing Mini-Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways Before you begin, power off the services gateway.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Unplug the power adapter from the services gateway. Verify that the Power LED is off. Label the cables connected to the Mini-PIM so that you can later reconnect each cable to the correct Mini-PIM.
CHAPTER 15 Replacing Gigabit-Backplane Physical Interface Modules Replacing Gigabit-Backplane Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways on page 99 Replacing Gigabit-Backplane Physical Interface Modules on the SRX300 Series and SRX550 High Memory Services Gateways...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 51: LED Indications for Hot-Swappable GPIM Components (continued) Number Component Description ONLINE/OFFLINE Push the button to turn the GPIM offline. After the STATUS button LED light goes off, it is safe to remove the GPIM from the services gateway.
Page 119
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, “Preventing Electrostatic Discharge Damage to the SRX300 Series and SRX550 High Memory Services Gateway” on page Grasp the handles on each side of the GPIM faceplate, and align the edges of the GPIM circuit board with the guide rails at each side of the GPIM slot.
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Table 52: Hot-Swappable Component Descriptions for GPIMs Number Component Description STATUS LED The STATUS LED has the following indicator s: Steady green indicates that the GPIM is functioning normally. Steady yellow indicates that the GPIM is starting up, running diagnostics, or going offline.
Contacting Customer Support Once you have located the serial numbers of the services gateway or component, you can return them for repair or replacement. For this, you need to contact Juniper Networks Technical Assistance Center (JTAC). You can contact JTAC 24 hours a day, 7 days a week, using any of the following methods: On the Web: Using the Case Manager link at http://www.juniper.net/support/...
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Locating the SRX Series Services Gateway Hardware Component Mini-PIM or GPIM Serial Number Label on page 107 Information You Might Need to Supply to JTAC on page 107 Packing the SRX Series Services Gateway Hardware Components for Shipment on...
Contacting Customer Support on page 105 Information You Might Need to Supply to JTAC If you are returning a hardware component to Juniper Networks for repair or replacement, obtain a Return Materials Authorization (RMA) number from Juniper Networks Technical Assistance Center (JTAC).
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference Configuration data displayed by one or more commands show Your name, organization name, telephone number, fax number, and shipping address Related Return Procedure for SRX Series Services Gateway Hardware Components on page 106...