MX480 AC Power Supply LEDs

Table 13: AC Power Supply LEDs

Label
Color
Yellow
AC OK
Green
Green
DC OK
PS FAIL
Red

AC Electrical Specifications for the MX480 Router

Copyright © 2019, Juniper Networks, Inc.
configuration with full power for as long as the router is operational. In the two-PEM
high-line configuration, slots
configuration requires two power supplies, with the third and fourth providing
redundancy. With high-capacity power supplies, you must have a minimum of two
power supplies installed in the router.
Each AC power supply faceplate contains three LEDs that indicate the status of the
power supply (see
Table 13 on page
LEDs on the craft interface. In addition, a power supply failure triggers the red alarm LED
on the craft interface.
State
Description
Off
AC power input voltage is below 78 VAC.
On
AC power input voltage is within 78–264 VAC.
Off
DC power outputs generated by the power supply are not within the normal
operating ranges.
On
DC power outputs generated by the power supply are within the normal operating
ranges.
Off
Power supply is functioning normally.
On
Power supply is not functioning normally and its output voltage is out of regulation
limits. Check
Table 14 on page 47
lists the AC power supply electrical specifications;
lists the AC power system specifications.

Table 14: AC Power Supply Electrical Specifications

Item
Normal-Capacity Power Supplies
Maximum output power
AC input voltage
AC input line frequency
AC input current rating
and
or
PEM0
PEM1
PEM2
47). The power supply status is also reflected in two
and
LEDs for more information.
AC OK
DC OK
Specification
1027 W (low line)
1590 W (high line)
Operating range: 100 – 240 VAC (nominal)
50 to 60 Hz (nominal)
11.0 A @ 200 VAC or 14.5 A @ 110 VAC maximum
Chapter 1: Overview
and
are used. The high-line
PEM3
Table 15 on page 48
47

Advertisement

Table of Contents
loading