Juniper MX10004 Hardware Manual page 160

Universal routing platform
Hide thumbs Also See for MX10004:
Table of Contents

Advertisement

that the power supply faceplate is flush with any adjacent power supply faceplates or power supply
covers (see
Figure 58 on page
Figure 58: Install a JNP10K-PWR-AC2
8.
Push the captive screw into the power supply faceplate. Ensure that the screw is seated inside the
corresponding hole on the faceplate.
9.
Tighten the captive screw by turning it clockwise with the Phillips (+) screwdriver, number 1. When
the screw is completely tight, the latch locks into the router chassis.
10. Attach each power cable to a dedicated power source (A and B). The JNP10K-PWR-AC2 only
requires that each power supply be connected to a separate source.
11. For each power cable, insert the end of the cable with the Anderson connector into the JNP10K-
PWR-AC2 power supply. The connector snaps and locks the cable into position.
WARNING: Ensure that the power cords do not block access to router components
or drape where people can trip on them.
12. If the AC or DC power source outlets have a power switch, set them to the on (|) position.
13. Set the three DIP switches to set the inputs and whether the power supply is running at 3000 W,
5000 W, or 5500 W. See
Set both switch 1 and switch 2 to the on position when using both power source inputs; power is
shared. When not using source redundancy, set the unused source to the off (O) position. The LED
turns red and indicates an error if a source input is not in use and the DIP switch is on (|).
150).
Table 50 on page
151.
150

Advertisement

Table of Contents
loading

Table of Contents