Nortel Meridian SL-100 SE Replacement page 90

Commercial systems card replacement procedures
Table of Contents

Advertisement

Replacing a line card in an IPE module
At your current location
1
2
At the MAP terminal
3
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
DANGER
Module front and rear covers are not hinged
Module front and rear covers are not hinged; do not
let go of the cover. Lift the cover away from the
module, and set the cover out of the work area.
CAUTION
Removal of in-service line cards
Removing an in-service line card may cause up to 16
subscribers to be removed from service.
Proceed only if you have been directed to this card replacement
procedure from a step in a maintenance procedure, are using
the procedure for verifying or accepting cards, or have been
directed to this procedure by your maintenance support group.
Obtain a replacement card. Ensure that the replacement card
has the same product equipment code (PEC), including suffix,
as the card to be removed.
Note: If the new IPE card does not have a PEC identical to
the one replaced, make sure PEC is datafilled in the
IPECARDS table before returning the card to service.
Set the MAP terminal to the LTP level by typing the following
string:
MAPCI;MTC;LNS;LTP;POST
and pressing the Enter key.
where
len
is the line equipment number (LEN) of the IPE line card
Example of a MAP display:
IPE card replacement procedures 90
in an IPE module
L
len
Line cards
(continued)