Card Settings - Nortel Meridian SL-100 SE Replacement

Commercial systems card replacement procedures
Table of Contents

Advertisement

100 IPE card replacement procedures
NT5D11
in an IPE
(continued)

Card settings

Tables Table , "Settings for DIP switch 1," on page -100 through Table ,
"CPE or CSU distance settings," on page -102 give the switch settings
for the DIP switches on the line side T-1 card. These switches must be
configured for your environment before you install the T-1 card, as
explained in Step Procedure 9, "Configure the DIP switches on the
replacement card as appropriate for your environment according to the
settings shown in Tables through in the "Card settings" section of this
chapter.," on page -105 of this procedure. They are located in the upper
right-hand corner of the card.
Settings for DIP switch 1
Switch
position
Characteristic
1
HMI port speed selection 1200 baud
2
T-1 signaling
3 - 6
IPE shelf address
8
Cutoff on disconnect
Note: Switch 7 is not used and should be left in the "off" position.
IPE shelf addresses (Sheet 1 of 2)
IPE shelf
address
00
01
02
03
555-4031-547 Standard 12.02 July 2002
Selection
2400 baud
Ground start
Loop start
See Table Table , "IPE shelf
addresses," on page -100
COD enabled
COD disabled
Switch 6
Switch 5
position
position
Off
Off
Off
Off
Off
Off
Off
Off
Switch
setting
On
Off
On
Off
On
Off
Switch 4
Switch 3
position
position
Off
Off
Off
On
On
Off
On
On