20 XPM card replacement procedures
NTAX78AA
in a DTCI shelf
Replacing an NTAX78AA in a DTCl shelf
At the MAP terminal
1
PM
DTCI
DTCI
Unit 0:
Unit 1:
2
3
555-4031-547 Standard 12.02 July 2002
(continued)
Access the PM level of the MAP terminal and post the PM that
contains the card to be replaced by typing
>MAPCI;MTC;PM;POST
and pressing the Enter key.
where
pm_type
is the PM type (DTCI, DTC7)
pm_no
is the PM identification number (0 to 999)
Example of a MAP terminal display input:
MAPCI;MTC;PM;POST DTCI 0
Example of a MAP terminal response:
SysB
ManB
1
0
1
0
0 ISTb
Links_OOS: CSide
Act
Insv
Inact SysB
Check the status of the PM.
If PM status is
SysB, OffL, CBsy, ISTb, or InSv
ManB
Determine whether the card you are replacing is in the active or
inactive unit of the PM.
If card is in the
active unit
inactive unit
pm_type
pm_no
OffL
CBsy
ISTb
7
0
0
0
0,
Pside 1
Do
step 3
step 7
Do
step 4
step 6
InSv
7
4
2
0