Nortel Meridian SL-100 SE Replacement page 180

Commercial systems card replacement procedures
Table of Contents

Advertisement

Replacing an NT6X69 card in an MCRM-S RCC2
At your current location
1
2
At the MAP terminal
3
> MAPCI;MTC;PM;POST RCC2 rcc2_no
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
MCRM-S card replacement procedures 180
CAUTION
Loss of subscriber service
Subscriber service may be lost in the active
unit when reseating the NT6X69 card.It is
recommended that this procedure be
performed during low traffic periods.
Proceed only if you have been directed to this card replacement
procedure from a step in a maintenance procedure, are using
the procedure for verifying or accepting cards, or have been
directed to this procedure by your maintenance support group.
CAUTION
Loss of service
When replacing a card in the RCC2, ensure
that the unit in which you are replacing the
card is inactive and that the mate unit is
active.
Obtain a replacement card. Ensure that the replacement card
has the same product engineering code (PEC), including suffix,
as the card to be removed.
Set the MAP terminal to the peripheral module (PM) level and
post the RCC2 by typing the following string:
and pressing the Enter key.
where
in an MCRM-S RCC2
NT6X69
(continued)

Advertisement

Table of Contents
loading

Table of Contents