Nortel Meridian SL-100 SE Replacement page 266

Commercial systems card replacement procedures
Table of Contents

Advertisement

Replacing an NTMX73 in an MCRM-S RCC2
At your current location
1
2
At the MAP terminal
3
4
5
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
MCRM-S card replacement procedures 266
Proceed only if you have been directed to this card replacement
procedure from a step in a maintenance procedure, are using
the procedure for verifying or accepting cards, or have been
directed to this procedure by your maintenance support group.
CAUTION
Loss of service
When replacing a card in the RCC2, ensure
that the unit in which you are replacing the
card is inactive and that the mate unit is
active.
Obtain a replacement card. Ensure that the replacement card
has the same product engineering code (PEC), including suffix,
as the card to be removed.
Set the MAP terminal to the peripheral module (PM) level and
post the RCC2 by typing the following string:
>MAPCI;MTC;PM;POST RCC2 rcc2_no
and pressing the Enter key.
where
rcc_unit_no
is the number of the unit to be loaded (0 or 1)
When both units are in-service, proceed to Step 4.
By observing the MAP display, be sure that the card that is to be
removed is on the inactive unit.
Use the following information to determine where to proceed.
If faulty card is on
active unit
inactive unit
in an MCRM-S RCC2
Do
Step 6
Step 7
NTMX73
(continued)